Precision of extracting absorption profiles from weakly scattering media with spectroscopic time-domain optical coherence tomography

被引:41
作者
Hermann, B [1 ]
Bizheva, K [1 ]
Unterhuber, A [1 ]
Povazay, B [1 ]
Sattmann, H [1 ]
Schmetterer, L [1 ]
Fercher, AF [1 ]
Drexler, W [1 ]
机构
[1] Vienna Univ Med, Christian Doppler Lab, Dept Med Phys, A-1090 Vienna, Austria
来源
OPTICS EXPRESS | 2004年 / 12卷 / 08期
关键词
D O I
10.1364/OPEX.12.001677
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The feasibility of spectroscopic optical coherence tomography (SOCT) to quantify spatially localized absorption profiles of chromophores embedded in weakly scattering media with a single measurement over the full spectral bandwidth of the light source was investigated by using a state-of-the-art ultra-broad bandwidth Ti: Al2O3 laser (lambda(c) = 800 nm, Deltalambda = 260 nm, P-out = 120 mW ex- fiber). The precision of the method as a function of the chromophore absorption, the sample thickness, and different parameters related to the measurement procedure was evaluated both theoretically and experimentally in single and multilayered phantoms. It is demonstrated that in weakly scattering media SOCT is able to extract mu(a)(lambda) as small as 0.5 mm(-1) from 450 mum thick phantoms with a precision of similar to2% in the central and similar to8% at the edges of the used wavelength region. As expected, in phantoms with the same absorption properties and thickness similar to180 mum the precision of SOCT decreases to >10% in the central wavelength region. (C) 2004 Optical Society of America.
引用
收藏
页码:1677 / 1688
页数:12
相关论文
共 18 条
[1]   Compact, broad-bandwidth fiber laser for sub-2-μm axial resolution optical coherence tomography in the 1300-nm wavelength region [J].
Bizheva, K ;
Povazay, B ;
Hermann, B ;
Sattmann, H ;
Drexler, W ;
Mei, M ;
Holzwarth, R ;
Hoelzenbein, T ;
Wacheck, V ;
Pehamberger, H .
OPTICS LETTERS, 2003, 28 (09) :707-709
[2]  
BIZHEVA K, 2002, OSA BIOM TOP M OPT S, P290
[3]  
Boulnois J L, 1983, Minerva Med, V74, P1669
[4]   Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography [J].
Faber, DJ ;
Mik, EG ;
Aalders, MCG ;
van Leeuwen, TG .
OPTICS LETTERS, 2003, 28 (16) :1436-1438
[5]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI [10.1088/0034-4885/66/2/204, 10.2184/lsj.31.635]
[6]  
FUJI T, 2003, APPL PHYS B
[7]   OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY [J].
FUJIMOTO, JG ;
BREZINSKI, ME ;
TEARNEY, GJ ;
BOPPART, SA ;
BOUMA, B ;
HEE, MR ;
SOUTHERN, JF ;
SWANSON, EA .
NATURE MEDICINE, 1995, 1 (09) :970-972
[8]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[9]  
KULKARNI MD, 1996, C LAS EL OPT, V9, P59
[10]   LIGHT-ABSORBING PROPERTIES, STABILITY, AND SPECTRAL STABILIZATION OF INDOCYANINE GREEN [J].
LANDSMAN, MLJ ;
KWANT, G ;
MOOK, GA ;
ZIJLSTRA, WG .
JOURNAL OF APPLIED PHYSIOLOGY, 1976, 40 (04) :575-583