Imaging procedures in cochlear implant patients - Evaluation of different radiological techniques

被引:44
作者
Aschendorff, A
Kubalek, R
Hochmuth, A
Bink, A
Kurtz, C
Lohnstein, P
Klenzner, T
Laszig, R
机构
[1] Univ Freiburg, Dept Otorhinolaryngol, D-79106 Freiburg, Germany
[2] Hosp Harlaching Munchen, Dept Neurol, Munich, Germany
[3] Univ Freiburg, Dept Neuroradiol, Freiburg, Germany
[4] Univ Frankfurt, Dept Neuroradiol, D-6000 Frankfurt, Germany
[5] Univ Freiburg, Dept Radiol, Freiburg, Germany
关键词
cochlear implant; imaging; computed tomography; temporal bone; rotational tomography; electrode;
D O I
10.1080/03655230410017175
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The purpose of this study was to evaluate the feasibility and usability of different radiologic methods (single-slice computed tomography (CT), multi-slice CT and rotational tomography (RT)) for assessment of the position of cochlear implant electrodes. Cochlear implants in an isolated human temporal bone and in a complete formalin-fixed cadaver head were examined and the electrode position was determined. Subsequently, the labyrinth bone was isolated out of the cadaver head and histologically examined to compare the results of histology with imaging. Single-slice CT reliably identifies the electrode inside the human cochlea; however, due to the technically based large electrode artifact its position inside the cochlear spaces (e.g. electrode position in scala tympani or scala vestibuli) cannot be detected. Multi-slice CT of the cadaver head also showed artifacts that complicate the assessment of electrode position. Using RT the electrode artifact is small and therefore the electrode position within the cochlear spaces, scala tympani versus scala vestibuli, can be assessed. This technique was also applicable in a complete cadaver head, which is in contrast with former studies. In conclusion, CT allows the identification of electrode arrays inside the human cochlea. Multi-slice CT permits a much more precise depiction of the electrode inside the cochlea. RT alone has minimized electrode artifacts to a high extent and permits the assessment of the electrode position within the scala tympani or scala vestibuli. As RT was performed successfully in a complete cadaver head, further studies for evaluation of the intracochlear electrode position can now be performed in patients.
引用
收藏
页码:46 / 49
页数:4
相关论文
共 11 条
[1]   Evaluation of the HiFocus® electrode array with positioner in human temporal bones [J].
Aschendorff, A ;
Klenzner, T ;
Richter, B ;
Kubalek, R ;
Nagursky, H ;
Laszig, R .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2003, 117 (07) :527-531
[2]   The Clarion electrode positioner: Temporal bone studies [J].
Fayad, JN ;
Luxford, W ;
Linthicum, FH .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :226-229
[3]  
Gstoettner WK, 2001, ACTA OTO-LARYNGOL, V121, P216
[4]   Nondestructive three-dimensional analysis of electrode to modiolus proximity [J].
Husstedt, HW ;
Aschendorff, A ;
Richter, B ;
Laszig, R ;
Schumacher, M .
OTOLOGY & NEUROTOLOGY, 2002, 23 (01) :49-52
[5]  
Hüttenbrink KB, 2002, OTOL NEUROTOL, V23, P187
[6]   Clarion 1.2® standard electrode array with partial space-filling positioner:: radiological and histological evaluation in human temporal bones [J].
Richter, B ;
Aschendorff, A ;
Lohnstein, P ;
Husstedt, H ;
Nagursky, H ;
Laszig, R .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2002, 116 (07) :507-513
[7]   Cochlear structures after implantation of a perimodiolar electrode array [J].
Richter, B ;
Jaekel, K ;
Aschendorff, A ;
Marangos, N ;
Laszig, R .
LARYNGOSCOPE, 2001, 111 (05) :837-843
[8]   The Nucleus Contour electrode array: A radiological and histological study [J].
Richter, B ;
Aschendorff, A ;
Lohnstein, P ;
Husstedt, H ;
Nagursky, H ;
Laszig, R .
LARYNGOSCOPE, 2001, 111 (03) :508-514
[9]   Electrode to modiolus proximity: A fluoroscopic and histologic analysis [J].
Roland, JT ;
Fishman, AJ ;
Alexiades, G ;
Cohen, NL .
AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (02) :218-225
[10]   CT-derived estimation of cochlear morphology and electrode array position in relation to word recognition in nucleus-22 recipients [J].
Skinner, MW ;
Ketten, DR ;
Holden, LK ;
Harding, GW ;
Smith, PG ;
Gates, GA ;
Neely, JG ;
Kletzker, GR ;
Brunsden, B ;
Blocker, B .
JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2002, 3 (03) :332-350