摘要
Biomedical function imaging and tracer kinetic modeling with Positron Emission Tomography (PET) are based on continuous data acquisition and time accumulated counts measurements. In dynamic cardiac studies, both the model input and output measurements are obtained simultaneously from the same sequence of PET images. In this paper, techniques in general PET optimal sampling schedule design for tracer kinetic modeling, based on continuous data acquisition and time accumulated counts measurements, are introduced. A special case in which simultaneous optimal sampling schedule design is required for both input and output measurements is also introduced. Copyright (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1759 / 1766
页数:8
相关论文
共 18 条
[1]  
[Anonymous], 1983, MATH MODELING METABO
[2]   THE EFFECTS OF MEASUREMENT ERRORS IN THE PLASMA RADIOACTIVITY CURVE ON PARAMETER-ESTIMATION IN POSITRON EMISSION TOMOGRAPHY [J].
CHEN, K ;
HUANG, SC ;
YU, DC .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09) :1183-1200
[3]   NEW ESTIMATION METHODS THAT DIRECTLY USE THE TIME ACCUMULATED COUNTS IN THE INPUT FUNCTION IN QUANTITATIVE DYNAMIC PET STUDIES [J].
CHEN, KW ;
HUANG, SC ;
FENG, DG .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11) :2073-2090
[4]  
CHOI Y, 1991, J NUCL MED, V32, P733
[5]   OPTIMAL-DESIGN OF MULTIOUTPUT SAMPLING SCHEDULES - SOFTWARE AND APPLICATIONS TO ENDOCRINE METABOLIC AND PHARMACOKINETIC MODELS [J].
COBELLI, C ;
RUGGERI, A ;
DISTEFANO, JJ ;
LANDAW, EM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (04) :249-256
[6]   EXPERIMENTAL-DESIGN OPTIMIZATION - THEORY AND APPLICATION TO ESTIMATION OF RECEPTOR MODEL PARAMETERS USING DYNAMIC POSITRON EMISSION TOMOGRAPHY [J].
DELFORGE, J ;
SYROTA, A ;
MAZOYER, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (04) :419-435
[7]   OPTIMIZED BLOOD-SAMPLING PROTOCOLS AND SEQUENTIAL DESIGN OF KINETIC-EXPERIMENTS [J].
DISTEFANO, JJ .
AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 240 (05) :R259-R265
[8]   MODELS FOR COMPUTER-SIMULATION STUDIES OF INPUT FUNCTIONS FOR TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY [J].
FENG, D ;
HUANG, SC ;
WANG, XM .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1993, 32 (02) :95-110
[9]   A new double modeling approach for dynamic cardiac PET studies using noise and spillover contaminated LV measurements [J].
Feng, DG ;
Li, XJ ;
Huang, SC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (03) :319-327
[10]   A COMPUTER-SIMULATION STUDY ON THE INPUT FUNCTION SAMPLING SCHEDULES IN TRACER KINETIC MODELING WITH POSITRON EMISSION TOMOGRAPHY (PET) [J].
FENG, DG ;
WANG, XM ;
YAN, H .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1994, 45 (03) :175-186