Continuous Glucose Sensing: Future Technology Developments

被引:28
作者
Brauker, Jim [1 ]
机构
[1] DexCom Inc, San Diego, CA 92121 USA
关键词
INTENSIVE INSULIN THERAPY; NEEDLE-TYPE; SENSOR; ACCURACY; DELIVERY; ADULTS; SYSTEM; LOOP;
D O I
10.1089/dia.2008.0137
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The data from blood glucose meters are discontinuous, providing only an estimate of the "amount'' of glucose. Continuous sensors provide time series data, including "amount,'' but adding direction, rate of change, and rate of acceleration. Currently, continuous sensor labeling requires a fingerstick confirmation for treatment decisions and for periodic calibration. Because of the added information, sensors may be as efficacious and safe as meters when used for treatment decisions but have not yet been tested in stand-alone mode. Glucose sensors are currently in the early adopter's phase of technology development. To extend to the broader diabetes patient population, improvements are needed in reliability, comfort, ease of use, and integration with other technologies. In order to achieve a closed loop (artificial pancreas), the "Holy Grail'' of the diabetes device industry, improvements in the accuracy of continuous sensors are also required. The main source of sensor inaccuracy is the calibration process. Calibration updates during the sensor wear period are required because of the gross changes in local metabolism (during the formation of the foreign body response) around the sensors after insertion and during the entire period of wear. Ambulatory sensors are currently approved and used only to treat insulin-using diabetes patients. In the future, the technology may have benefit for diagnostic use and behavior modification in obesity, metabolic syndrome, and prediabetes, as well as metabolic monitoring in elite athletes, soldiers, pilots, and the like. Hospitals currently use single-point information for tracking glucose in patients. Blood-based continuous sensing may provide the data needed to prevent in-hospital hypoglycemia and may lead to closed loop technology in the hospital.
引用
收藏
页码:S25 / S36
页数:12
相关论文
共 30 条
[11]   The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes [J].
Mastrototaro, John ;
Shin, John ;
Marcus, Alan ;
Sulur, Giri .
DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) :385-390
[12]   The Chemistry of Commercial Continuous Glucose Monitors [J].
McGarraugh, Geoffrey .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 :S17-S24
[13]  
PANTELEON AE, 2006, DIABETES S, V55, pP406
[14]   A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose [J].
Parkes, JL ;
Slatin, SL ;
Pardo, S ;
Ginsberg, BH .
DIABETES CARE, 2000, 23 (08) :1143-1148
[15]  
Renard E, 2002, DIABETES, V51, pA126
[16]   Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy [J].
Renard, E .
CURRENT OPINION IN PHARMACOLOGY, 2002, 2 (06) :708-716
[17]   THE EFFECT OF INTENSIVE TREATMENT OF DIABETES ON THE DEVELOPMENT AND PROGRESSION OF LONG-TERM COMPLICATIONS IN INSULIN-DEPENDENT DIABETES-MELLITUS [J].
SHAMOON, H ;
DUFFY, H ;
FLEISCHER, N ;
ENGEL, S ;
SAENGER, P ;
STRELZYN, M ;
LITWAK, M ;
WYLIEROSETT, J ;
FARKASH, A ;
GEIGER, D ;
ENGEL, H ;
FLEISCHMAN, J ;
POMPI, D ;
GINSBERG, N ;
GLOVER, M ;
BRISMAN, M ;
WALKER, E ;
THOMASHUNIS, A ;
GONZALEZ, J ;
GENUTH, S ;
BROWN, E ;
DAHMS, W ;
PUGSLEY, P ;
MAYER, L ;
KERR, D ;
LANDAU, B ;
SINGERMAN, L ;
RICE, T ;
NOVAK, M ;
SMITHBREWER, S ;
MCCONNELL, J ;
DROTAR, D ;
WOODS, D ;
KATIRGI, B ;
LITVENE, M ;
BROWN, C ;
LUSK, M ;
CAMPBELL, R ;
LACKAYE, M ;
RICHARDSON, M ;
LEVY, B ;
CHANG, S ;
HEINHEINEMANN, M ;
BARRON, S ;
ASTOR, L ;
LEBECK, D ;
BRILLON, D ;
DIAMOND, B ;
VASILASDWOSKIN, A ;
LAURENZI, B .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 329 (14) :977-986
[18]   TELEMETRY GLUCOSE MONITORING DEVICE WITH NEEDLE-TYPE GLUCOSE SENSOR - A USEFUL TOOL FOR BLOOD-GLUCOSE MONITORING IN DIABETIC INDIVIDUALS [J].
SHICHIRI, M ;
ASAKAWA, N ;
YAMASAKI, Y ;
KAWAMORI, R ;
ABE, H .
DIABETES CARE, 1986, 9 (03) :298-301
[19]   Benefits and risks of tight glucose control in critically ill adults - A meta-analysis [J].
Soylemez Wiener, Renda ;
Wiener, Daniel C. ;
Larson, Robin J. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 300 (08) :933-944
[20]  
Steil Garry M, 2003, Diabetes Technol Ther, V5, P27, DOI 10.1089/152091503763816436