Speciation of selenium compounds by open tubular capillary electrochromatography-inductively coupled plasma mass spectrometry

被引:11
作者
Lin, Shu-Yu [1 ]
Wang, Guan-Ren [1 ]
Huang, Quan-Pin [1 ]
Liu, Chuen-Ying [1 ]
机构
[1] Natl Taiwan Univ, Dept Chem, Taipei 10617, Taiwan
关键词
crossflow nebulizer; inductively coupled plasma mass spectrometry; macrocyclic polyamine; open-tubular capillary electrochromatography; selenium speciation;
D O I
10.1002/elps.200600186
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We introduce a T-type interface and a crossflow nebulizer to find ways to combine CEC with inductively coupled plasma MS (ICP-MS) detection for selenium speciation. For CEC separation, we employed a macrocyclic polyamine-bonded phase capillary as the separation column and a bare fused-silica capillary filled with the make-up liquid (0.05 M HNO3). The effect of nebulizer gas flow rate, make-up liquid flow, type, concentration and pH of the mobile phase on the separation have been studied. Tris buffer of 50 mM at pH 8.50 gave the best performance for selenium speciation. The reproducibility of the retention time indicated that sample injection by electrokinetic and nebulizer gas flow was better than that by self-aspiration alone. The detection limits for selenate, selenite, selenocystine and selenomethionine were found to be 2.40, 3.53, 12.86 and 11.25 ng/mL, respectively. Due to the high sensitivity and element-specific detection, as well as the high selectivity of the bonded phase, quantitative analysis of selenium speciation in urine was also achieved.
引用
收藏
页码:4257 / 4265
页数:9
相关论文
共 42 条
[1]   ANALYSIS OF ORGANIC AND NONORGANIC ARSENIOUS OR SELENIOUS COMPOUNDS BY CAPILLARY ELECTROPHORESIS [J].
ALBERT, M ;
DEMESMAY, C ;
ROCCA, JL .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (4-5) :426-432
[2]   ICP-MS for specific detection in capillary electrophoresis [J].
Alvarez-Llamas, G ;
de laCampa, MD ;
Sanz-Medel, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (01) :28-36
[3]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[4]   Separation of selenium compounds by CE-ICP-MS in dynamically coated capillaries applied to selenized yeast samples [J].
Bendahl, L ;
Gammelgaard, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :143-148
[5]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[6]   Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se- and Te-species, applicable to soil extracts [J].
Casiot, C ;
Donard, OFX ;
Potin-Gautier, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) :173-187
[7]   Sensitivity enhancement in capillary electrophoresis-inductively coupled plasma-mass spectrometry for metal/protein interactions analysis by using large volume stacking with polarity switching [J].
Chamoun, J ;
Hagège, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (10) :1030-1034
[8]   Macrocyclic polyamine as a selective modifier in a bonded-phase capillary column for the electrophoretic separation of aromatic acids [J].
Chen, WH ;
Liu, CY .
JOURNAL OF CHROMATOGRAPHY A, 1999, 848 (1-2) :401-416
[9]   Capillary electrochromatographic separation of metal ion species with on-line detection by inductively coupled plasma mass spectrometry [J].
Chen, WH ;
Lin, SY ;
Liu, CY .
ANALYTICA CHIMICA ACTA, 2000, 410 (1-2) :25-35
[10]   Capillary electrochromatographic analysis of aliphatic mono- and polycarboxylic acids [J].
Chen, WH ;
Lin, CC ;
Chen, TS ;
Misra, TK ;
Liu, CY .
ELECTROPHORESIS, 2003, 24 (06) :970-977