ICP-MS for specific detection in capillary electrophoresis

被引:84
作者
Alvarez-Llamas, G [1 ]
de laCampa, MD [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
capillary electrophoresis; CE-ICP-MS coupling; hybrid techniques; inductively coupled plasma; mass spectrometry; speciation analysis; trace element;
D O I
10.1016/j.trac.2004.09.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The advantages of capillary electrophoresis (CE) as a powerful separation technique can be combined with the atomic specificity, multi-elemental character and extremely high sensitivity of an inductively coupled plasma mass spectrometry (ICP-MS) detector for metal-speciation studies in different fields of interest. However, the coupling of both commercially available instruments deserves particular attention if separative resolution, high analyte transport efficiency and sensitive detection are to be achieved. In that technical vein, the interface itself may be considered as the "key to success". We review the different ways of performing CE-ICP-MS coupling so far and discuss interfaces based on conventional, micronebulizers and the generation of volatile species of analytes. We pay particular attention to those contributions aimed at improving the sensitivity achieved in CE-ICP-MS couplings. Finally, we review the latest applications (as reported from 2002 to June 2004) of CE-ICP-MS to tackle trace-element-speciation problems. It appears that initial technical problems for coupling CE to ICP-MS have now been overcome, so we expect an increasing number of applications of the technique in the field of trace-element speciation in the near future. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 54 条
[1]   Sample stacking capillary electrophoresis with ICP-(Q) MS detection for Cd, Cu and Zn speciation in fish liver metallothioneins [J].
Alvarez-Llamas, G ;
de la Campa, MDF ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (05) :460-466
[2]   Comparison of two CE-ICP-MS interfaces based on microflow nebulizers:: application to cadmium speciation in metallothioneins using quadrupole and double focusing mass analyzers [J].
Alvarez-Llamas, G ;
de la Campa, MRF ;
Sánchez, MLF ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :655-661
[3]  
Alvarez-Llamas G., 2004, ANAL DETECTION CAPIL
[4]   Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry [J].
B'Hymer, C ;
Day, JA ;
Caruso, JA .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1040-1046
[5]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[6]   Separation of selenium compounds by CE-ICP-MS in dynamically coated capillaries applied to selenized yeast samples [J].
Bendahl, L ;
Gammelgaard, B .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :143-148
[7]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[8]   Gas chromatography with inductively coupled plasma mass spectrometric detection in speciation analysis [J].
Bouyssiere, B ;
Szpunar, J ;
Lobinski, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (05) :805-828
[9]   Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se- and Te-species, applicable to soil extracts [J].
Casiot, C ;
Donard, OFX ;
Potin-Gautier, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) :173-187
[10]  
Cornelis R., 2003, HDB ELEMENTAL SPECIA