Comparison of two CE-ICP-MS interfaces based on microflow nebulizers:: application to cadmium speciation in metallothioneins using quadrupole and double focusing mass analyzers

被引:25
作者
Alvarez-Llamas, G [1 ]
de la Campa, MRF [1 ]
Sánchez, MLF [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/b202916b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different interfaces, based on microflow nebulizers, were investigated in detail and compared for metal speciation studies by CZE-ICP-(Q)MS and CZE-ICP-(DF) MS. The model species selected were rabbit liver metallothioneins (MTs). Small differences among MT sub-isoforms determine the need for an adequate interface, which is critical if the resolution achieved (e. g., by UV) is to be maintained with ICP-MS detection. HEN and MicroMist nebulizers were compared to interface the flows emerging from the CE capillary with the ICP-MS instrument. The observed analytical characteristics of the hybrid systems were compared in terms of calibration graphs, resolution, repeatability and detection limits (DLs). The separation profiles matched perfectly those obtained with UV detection for both interfaces under scrutiny. Similar performances were observed by CE-ICP-(Q)MS in terms of resolution and DLs achieved. The MicroMist interface proved to offer better performance than the HEN-based one using the ICP-(DF) MS instrument, because the introduction of an additional Ar "make-up'' gas into the spray chamber is not required (very important if the HEN-based interface is used). In general terms, the MicroMist interface was easier to operate, providing the best DLs for Cd (about 2 pg in each isoform by CE-ICP-( DF) MS, a value 6 times lower than that obtained in a quadrupole system).
引用
收藏
页码:655 / 661
页数:7
相关论文
共 44 条
[1]   Metallothionein isoforms separation and cadmium speciation by capillary electrophoresis with ultraviolet and quadrupole-inductively coupled plasma mass spectrometric detection [J].
Alvarez-Llamas, G ;
de la Campa, MRF ;
Sanz-Medel, A .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :105-119
[2]   Evaluation of a microconcentric nebulizer and its suction effect in a capillary electrophoresis interface with inductively coupled plasma mass spectrometry [J].
B'Hymer, C ;
Day, JA ;
Caruso, JA .
APPLIED SPECTROSCOPY, 2000, 54 (07) :1040-1046
[3]   The use of sol-gel frits to minimize suction effects in capillary electrophoresis-nebulizer interfaces for plasma spectrometry [J].
B'Hymer, C ;
Sutton, RMC ;
Sutton, KL ;
Caruso, JA .
ANALYTICAL COMMUNICATIONS, 1999, 36 (9-10) :349-353
[4]   Comparison of a cross-flow and microconcentric nebulizer for chemical speciation measurements using CZE-ICP-MS [J].
Baker, SA ;
Miller-Ihli, NJ .
APPLIED SPECTROSCOPY, 1999, 53 (04) :471-478
[5]   Capillary electrophoresis and inductively coupled plasma spectrometry: Status report [J].
Barnes, RM .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03) :246-251
[6]   Strategies for the qualitative and quantitative analysis of metallothionein isoforms by capillary electrophoresis [J].
Beattie, JH .
TALANTA, 1998, 46 (02) :255-270
[7]   Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation [J].
Bendahl, L ;
Gammelgaard, B ;
Jons, O ;
Farver, O ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :38-42
[8]   Non-spectral interference effects in inductively coupled plasma mass spectrometry using direct injection high efficiency and microconcentric nebulisation [J].
Björn, E ;
Frech, W .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) :4-11
[9]   Optimization of the hyphenation between capillary zone electrophoresis and inductively coupled plasma mass spectrometry for the measurement of As-, Sb-, Se- and Te-species, applicable to soil extracts [J].
Casiot, C ;
Donard, OFX ;
Potin-Gautier, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) :173-187
[10]  
da Rocha MS, 2000, J ANAL ATOM SPECTROM, V15, P513