Comparison of two CE-ICP-MS interfaces based on microflow nebulizers:: application to cadmium speciation in metallothioneins using quadrupole and double focusing mass analyzers

被引:25
作者
Alvarez-Llamas, G [1 ]
de la Campa, MRF [1 ]
Sánchez, MLF [1 ]
Sanz-Medel, A [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/b202916b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different interfaces, based on microflow nebulizers, were investigated in detail and compared for metal speciation studies by CZE-ICP-(Q)MS and CZE-ICP-(DF) MS. The model species selected were rabbit liver metallothioneins (MTs). Small differences among MT sub-isoforms determine the need for an adequate interface, which is critical if the resolution achieved (e. g., by UV) is to be maintained with ICP-MS detection. HEN and MicroMist nebulizers were compared to interface the flows emerging from the CE capillary with the ICP-MS instrument. The observed analytical characteristics of the hybrid systems were compared in terms of calibration graphs, resolution, repeatability and detection limits (DLs). The separation profiles matched perfectly those obtained with UV detection for both interfaces under scrutiny. Similar performances were observed by CE-ICP-(Q)MS in terms of resolution and DLs achieved. The MicroMist interface proved to offer better performance than the HEN-based one using the ICP-(DF) MS instrument, because the introduction of an additional Ar "make-up'' gas into the spray chamber is not required (very important if the HEN-based interface is used). In general terms, the MicroMist interface was easier to operate, providing the best DLs for Cd (about 2 pg in each isoform by CE-ICP-( DF) MS, a value 6 times lower than that obtained in a quadrupole system).
引用
收藏
页码:655 / 661
页数:7
相关论文
共 44 条
[11]   A comparison of capillary electrophoresis using indirect UV absorbance and ICP-MS detection with a self-aspirating nebulizer interface [J].
Day, JA ;
Sutton, KL ;
Soman, RS ;
Caruso, JA .
ANALYST, 2000, 125 (05) :819-823
[12]   Application of capillary electrophoresis interfaced to double focusing sector field ICP-MS for nuclide abundance determination of lanthanides produced via spallation reactions in an irradiated tantalum target [J].
Day, JA ;
Caruso, JA ;
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (10) :1343-1348
[13]   Speciation of metallothionein-like proteins of the mussel Mytilus edulis at basal levels by chromatographic separations coupled to quadrupole and double-focusing magnetic sector ICPMS [J].
Ferrarello, CN ;
de la Campa, MDF ;
Carrasco, JF ;
Sanz-Medel, A .
ANALYTICAL CHEMISTRY, 2000, 72 (24) :5874-5880
[14]   Effect of laminar flow in capillary electrophoresis: Model and experimental results on controlling analysis time and resolution with inductively coupled plasma mass spectrometry detection [J].
Kinzer, JA ;
Olesik, JW ;
Olesik, SV .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3250-3257
[15]   An evaluation of ultrasonic nebulizers as interfaces for capillary electrophoresis of inorganic anions and cations with inductively coupled plasma mass spectrometric detection [J].
Kirlew, PW ;
Castillano, MTM ;
Caruso, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :221-237
[16]   Investigation of a modified oscillating capillary nebulizer design as an interface for CE-ICP-MS [J].
Kirlew, PW ;
Caruso, JA .
APPLIED SPECTROSCOPY, 1998, 52 (05) :770-772
[17]   Determination of mercury compounds by capillary electrophoresis inductively coupled plasma mass spectrometry with microconcentric nebulization [J].
Lee, TH ;
Jiang, SJ .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :197-205
[18]   CAPILLARY ELECTROPHORESIS COUPLED ONLINE WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR ELEMENTAL SPECIATION [J].
LIU, Y ;
LOPEZAVILA, V ;
ZHU, JJ ;
WIEDERIN, DR ;
BECKERT, WF .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2020-2025
[19]   Evaluation of an ultrasonic nebulizer interface for capillary electrophoresis and inductively coupled plasma mass spectrometry [J].
Lu, QH ;
Barnes, RM .
MICROCHEMICAL JOURNAL, 1996, 54 (02) :129-143
[20]   INTERFACE FOR CAPILLARY ELECTROPHORESIS AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
LU, QH ;
BIRD, SM ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1995, 67 (17) :2949-2956