Solid-phase extraction study and photodiode array RP-HPLC analysis of xanthine derivatives in human biological fluids

被引:17
作者
Papadoyannis, IN
Samanidou, VF
Georga, KA
机构
[1] Laboratory of Analytical Chemistry, Chemistry Department, Aristotle University of Thessaloniki
关键词
PERFORMANCE LIQUID-CHROMATOGRAPHY; HUMAN-PLASMA; THEOPHYLLINE; CAFFEINE; METABOLITES; SERUM; QUANTITATION; PARAXANTHINE; THEOBROMINE; SEPARATION;
D O I
10.1080/10826079608014038
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated reverse phase high performance liquid chromatography (HPLC) - photodiode array method using a multi linear gradient elution is described for the simultaneous analysis of nine xanthines: xanthine, 7-methylxanthine, 3-methylxanthine, 1-methylxanthine, isocaffeine, theobromine, paraxanthine, theophylline and caffeine. The separation method development was based on mobile-phase optimisation and off-line solid-phase extraction (SPE) from human biological fluids: blood serum and urine. Eluent consisted of 0.05 M CH3COONH4 and methanol ( 90:10 v/v ) changing to ( 70:30 v/v ) over a period of 20 min. Identification of xanthines was achieved by photodiode - array detector and quantitation was performed at 270 nm. Isocaffeine was used as internal standard at a concentration of 3.06 ng/mu L. High extraction recoveries were achieved from Merck RP-18 cartridges using 1% hydrochloric acid as eluent, requiring small volumes, 40 mu L, of blood serum and 100 mu L of urine. The separation of xanthines was achieved on octylsilica, using a Silasorb C-8, 10 mu m, 250x4.6 mm i.d. analytical column thermostated at 32 degrees C and proved to be highly selective, sensitive, reproducible, accurate and rapid regarding the nine compounds. Detection limits ranged from 2 to 3 ng for 20 mu L injected volume while linearity holds up to 20 ng/mu L for each compound.
引用
收藏
页码:2559 / 2578
页数:20
相关论文
共 16 条
[1]   A RAPID AND SPECIFIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THEOPHYLLINE IN BIOLOGICAL-FLUIDS [J].
BLANCHARD, J ;
HARVEY, S ;
MORGAN, WJ .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1990, 28 (06) :303-306
[2]   QUANTIFICATION OF THEOPHYLLINE IN HUMAN PLASMA BY REVERSED-PHASE ION-INTERACTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COMPARISON WITH THE TDX FLUORESCENCE POLARIZATION IMMUNOASSAY PROCEDURE [J].
GENNARO, MC ;
ABRIGO, C ;
BIGLINO, P .
ANALYST, 1992, 117 (07) :1071-1074
[3]   SIMPLE AND SENSITIVE METHOD FOR THE SIMULTANEOUS DETERMINATION OF ENPROFYLLINE, THEOBROMINE, PARAXANTHINE, THEOPHYLLINE AND CAFFEINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GRGURINOVICH, N .
JOURNAL OF CHROMATOGRAPHY, 1986, 380 (02) :431-436
[4]   SIMULTANEOUS DETERMINATION OF CAFFEINE AND ITS N-DEMETHYLATED METABOLITES IN UMBILICAL-CORD PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARTLEY, R ;
COOKMAN, JR ;
SMITH, IJ .
JOURNAL OF CHROMATOGRAPHY, 1984, 306 (MAR) :191-203
[5]   LIQUID-CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE CONCENTRATION WITH SYRINGE-TYPE MINICOLUMNS FOR DIRECT PLASMA INJECTION [J].
HOMMA, M ;
OKA, K ;
TAKAHASHI, N .
ANALYTICAL CHEMISTRY, 1989, 61 (07) :784-787
[6]   NEW SIMPLIFIED MICROASSAY FOR THE QUANTITATION OF THEOPHYLLINE AND ITS MAJOR METABOLITES IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KESTER, MB ;
SACCAR, CL ;
ROCCI, ML ;
MANSMANN, HC .
JOURNAL OF CHROMATOGRAPHY, 1986, 380 (01) :99-108
[7]   ION-PAIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC PROCEDURE FOR THE QUANTITATIVE-ANALYSIS OF THEOPHYLLINE IN SERUM SAMPLES [J].
LAUFF, JJ .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 417 (01) :99-109
[8]   SIMULTANEOUS ANALYSIS OF THEOPHYLLINE, CAFFEINE AND 8 OF THEIR METABOLIC PRODUCTS IN HUMAN PLASMA BY GRADIENT HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LEAKEY, TEB .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :199-220
[9]   IMPROVED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THEOPHYLLINE IN PLASMA AND SALIVA IN THE PRESENCE OF CAFFEINE AND ITS METABOLITES AND COMPARISONS WITH 3 OTHER ASSAYS [J].
MUIR, KT ;
KUNITANI, M ;
RIEGELMAN, S .
JOURNAL OF CHROMATOGRAPHY, 1982, 231 (01) :73-82
[10]   REVERSED-PHASE LIQUID-CHROMATOGRAPHY USING MONOALKYLAMMONIUM COMPOUNDS IN THE MOBILE PHASE - EFFECTS OF MONOALKYLAMMONIUM CHAIN-LENGTH ON THE EFFICIENCY, SELECTIVITY AND SEPARATION OF XANTHINE AND URIC-ACID DERIVATIVES [J].
NALINE, E ;
PALETTEPAYS, C ;
MOREAU, J ;
ADVENIER, C ;
PAYS, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 604 (02) :203-211