Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model

被引:42
作者
Lazennec, Jean Y. [1 ]
Madi, Abdallah [1 ]
Rousseau, Marc A. [1 ]
Roger, Bernard [1 ]
Saillant, Gerard [1 ]
机构
[1] Hop La Pitie Salpetriere, Dept Orthopaed Surg, Paris, France
关键词
bioresorbable spinal cage; animal model; lumbar interbody fusion; polylactide; 96/4; PLDLLA;
D O I
10.1007/s00586-006-0145-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Arthrodesis using interbody cages has demonstrated high fusion rates. However, permanent cages are exposed to stress-shielding, corrosion, and may require explanation when necessary. Polylactic acid (PLA) bioresorbable cages are developed for avoiding these problems, but significant tissue reaction has been reported with 70/30 PLDLLA in some preclinical animal studies. The objective was to evaluate 96/4 PLDLLA cages in a sheep model over 3 years. Sixteen sheeps underwent one level anterior lumbar interbody fusion using 96/4 PLDLLA cages, filled and surrounded with cancellous bone graft from the iliac crest. Six groups of three animals were killed after 3, 6, 9, 12, 24, and 36 months. Harvested lumbar spine had radiographic, MRI, and CT evaluation and histological analysis. Histological results: cage swelling and slight signs of fragmentation associated to fibrocartilaginous tissue apposition at 3 months; bone remodeling around the cage with direct apposition of the mineralization front at 6 months; active cage degradation and complete fusion around the cage at 9 months; cage fragmentation and partial replacement by bone tissue at 12 months; bone bridges in and around the cage at 24 months; full resorption and intervertebral fusion at 36 months. Radiological results: partial arthrodesis at 3 months; definite peripheral arthrodesis at 6 months; similar aspect at 9 months; significant cage resorption at 12 months; definite inner and outer fusion at 24 months; complete cage resorption and calcification at the location of the cage at 36 months confirmed histological observations. Radiographic, CT scan, MRI, and histological data were consistent for showing progressive resorption of 96/4 PLDLLA, interbody fusion, and bone remodeling, with no significant signs of local intolerance reaction. These results are promising and suggest further development of 96/4 PLDLLA cages.
引用
收藏
页码:1545 / 1553
页数:9
相关论文
共 53 条
[1]
*AFNOR, 2005, J OFF REPUB FR, P70
[2]
Posterior lumbar interbody fusion with cages: an independent review of 71 cases [J].
Agazzi, S ;
Reverdin, A ;
May, D .
JOURNAL OF NEUROSURGERY, 1999, 91 (02) :186-192
[3]
Applications of a resorbable interbody spacer in posterior lumbar interbody fusion [J].
Alexander, JT ;
Branch, CL ;
Subach, BR ;
Haid, RW .
JOURNAL OF NEUROSURGERY, 2002, 97 (04) :468-472
[4]
Alexander JT, 2002, ORTHOPEDICS, V25, pS1185
[5]
Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices [J].
An, YH ;
Woolf, SK ;
Friedman, RJ .
BIOMATERIALS, 2000, 21 (24) :2635-2652
[6]
LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[7]
IN-VIVO DEGRADATION AND BIOCOMPATIBILITY STUDY OF IN-VITRO PRE-DEGRADED AS-POLYMERIZED POLYLACTIDE PARTICLES [J].
BERGSMA, JE ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G ;
DEBRUIJN, WC ;
PENNINGS, AJ .
BIOMATERIALS, 1995, 16 (04) :267-274
[8]
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation:: a review [J].
Böstman, O ;
Pihlajamäki, H .
BIOMATERIALS, 2000, 21 (24) :2615-2621
[9]
A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS [J].
BRANTIGAN, JW ;
STEFFEE, AD .
SPINE, 1993, 18 (14) :2106-2117
[10]
BIODEGRADABLE RODS VERSUS KIRSCHNER WIRE FIXATION OF WRIST FRACTURES - A RANDOMIZED TRIAL [J].
CASTELEYN, PP ;
HANDELBERG, F ;
HAENTJENS, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06) :858-861