Feasibility tests of transmission x-ray photoelectron emission microscopy of wet samples

被引:17
作者
De Stasio, G
Gilbert, B
Nelson, T
Hansen, R
Wallace, J
Mercanti, D
Capozi, M
Baudat, PA
Perfetti, P
Margaritondo, G
Tonner, BP
机构
[1] CNR, Ist Struttura Mat, I-00133 Rome, Italy
[2] Univ Wisconsin, Dept Phys, Madison, WI 53706 USA
[3] Ecole Polytech Fed Lausanne, Inst Phys Appl, CH-1015 Lausanne, Switzerland
[4] Univ Wisconsin, Ctr Synchrotron Radiat, Stoughton, WI 53589 USA
[5] CNR, Ist Neurobiol, I-00137 Rome, Italy
[6] Univ Cent Florida, Dept Phys, Orlando, FL 32718 USA
关键词
D O I
10.1063/1.1150151
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We performed feasibility tests of photoelectron emission spectromicroscopy of wet samples in the water window (285-532 eV) soft x-ray spectral region. Water was successfully confined in an ultrahigh vacuum compatible compartment with x-ray transparent sides. This water cell was placed in the MEPHISTO spectromicroscope in a transmission geometry, and complete x-ray absorption spectra of the water window region were acquired. We also show micrographs of test samples, mounted outside of the compartment, and imaged through the water. This technique can be used to study liquid chemistry and, at least to the micron level, the microstructure of wet samples. Possibilities include cells in water or buffer, proteins in solution, oils of tribological interest, liquid crystals, and other samples not presently accessible to the powerful x-ray photoelectron emission spectromicroscopy technique. (C) 2000 American Institute of Physics. [S0034-6748(00)04501-9].
引用
收藏
页码:11 / 14
页数:4
相关论文
共 11 条
  • [1] Crompton NEA, 1998, ACTA ONCOL, V37, P1
  • [2] MEPHISTO: Performance tests of a novel synchrotron imaging photoelectron spectromicroscope
    De Stasio, G
    Capozi, M
    Lorusso, GF
    Baudat, PA
    Droubay, TC
    Perfetti, P
    Margaritondo, G
    Tonner, BP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (05) : 2062 - 2066
  • [3] MEPHISTO spectromicroscope reaches 20 nm lateral resolution
    De Stasio, G
    Perfetti, L
    Gilbert, B
    Fauchoux, O
    Capozi, M
    Perfetti, P
    Margaritondo, G
    Tonner, BP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03) : 1740 - 1742
  • [4] Soft-x-ray transmission photoelectron spectromicroscopy with the MEPHISTO system
    De Stasio, G
    Gilbert, B
    Perfetti, L
    Fauchoux, O
    Valiquer, A
    Nelson, T
    Capozi, M
    Baudat, PA
    Cerrina, F
    Chen, Z
    Perfetti, P
    Tonner, BP
    Margaritondo, G
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (09) : 3106 - 3108
  • [5] An electron imaging approach to soft-x-ray transmission spectromicroscopy
    De Stasio, G
    Lorusso, GF
    Droubay, T
    Kohli, M
    Muralt, P
    Perfetti, P
    Margaritondo, G
    Kelly, TF
    Tonner, BP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03) : 737 - 741
  • [6] PHOTON MASS ATTENUATION AND MASS ENERGY-ABSORPTION COEFFICIENTS FOR H, C, N, O, AR, AND 7 MIXTURES FROM 0.1 KEV TO 20 MEV
    HUBBELL, JH
    [J]. RADIATION RESEARCH, 1977, 70 (01) : 58 - 81
  • [7] MEYERILSE W, 1998, XRAY SPECTROSCOPY SP
  • [8] ALTERATIONS IN ERYTHROCYTE-MEMBRANE LIPIDS INDUCED BY LOW-DOSES OF IONIZING-RADIATION AS REVEALED BY 1,6-DIPHENYL-1,3,5-HEXATRIENE FLUORESCENCE LIFETIME
    PARASASSI, T
    SAPORA, O
    GIUSTI, AM
    DE STASIO, G
    RAVAGNAN, G
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1991, 59 (01) : 59 - 69
  • [9] Tonner BP, 1999, SURF INTERFACE ANAL, V27, P247, DOI 10.1002/(SICI)1096-9918(199904)27:4<247::AID-SIA553>3.0.CO
  • [10] 2-M