MR-guided angioplasty of renal artery stenosis in a pig model: A feasibility study

被引:55
作者
Omary, RA
Frayne, R
Unal, O
Warner, T
Korosec, FR
Mistretta, CA
Strother, CM
Grist, TM
机构
[1] Univ Wisconsin, Dept Radiol, Sch Med, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Phys Med, Sch Med, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Pathol, Sch Med, Madison, WI 53706 USA
关键词
magnetic resonance (MR); vascular studies magnetic resonance (MR); guidance; renal arteries; stenosis or obstruction;
D O I
10.1016/S1051-0443(07)61433-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To test the hypothesis that magnetic resonance (MR) imaging can guide the percutaneous treatment of renal artery stenosis in a pig model. MATERIALS AND METHODS: Ameroid constrictors were surgically placed around six renal arteries in four pigs, After 30-36 days, all stenoses were documented by conventional x-ray aortograms. MR-guided renal angioplasty was attempted for three stenoses. For these pigs, MR angiography was performed with use of contrast-enhanced three-dimensional (3D) techniques, The authors visualized catheters by filling them with dilute 4% gadolinium and imaging with two-dimensional (2D) and 3D MR fast spoiled gradient recalled echo techniques. Under MR guidance, the authors advanced a selective catheter into the affected renal artery and crossed the stenosis with a nitinol guide wire. Angioplasty was performed with a balloon catheter filled with dilute gadolinium. Stenosis and luminal diameter measurements were compared before and after angioplasty. RESULTS: After ameroid constrictor placement, four significant stenoses, one mild stenosis, and one occlusion developed. Under MR guidance, the authors achieved technical success in performing three of three (100%) attempted dilations. After MR-guided angioplasty, the mean reduction in stenosis was 35% and the mean increase in luminal diameter was 1.6 mm. CONCLUSION: Use of MR guidance for the angioplasty of renal artery stenosis in pigs is feasible.
引用
收藏
页码:373 / 381
页数:9
相关论文
共 34 条
[11]  
HELLSTEN S, 1976, ACTA CHIR SCAND, V142, P375
[12]   MR-guided transjugular portosystemic shunt placement in a swine model [J].
Kee, ST ;
Rhee, JS ;
Butts, K ;
Daniel, B ;
Pauly, J ;
Kerr, A ;
O'Sullivan, GJ ;
Sze, DY ;
Razavi, MK ;
Semba, CP ;
Herfkens, RJ ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (05) :529-535
[13]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[14]   INTRAVASCULAR MR TRACKING CATHETER - PRELIMINARY EXPERIMENTAL EVALUATION [J].
LEUNG, DA ;
DEBATIN, JF ;
WILDERMUTH, S ;
MCKINNON, GC ;
HOLTZ, D ;
DUMOULIN, CL ;
DARROW, RD ;
HOFMANN, E ;
VONSCHULTHESS, GK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) :1265-1270
[15]   NEW NEEDLE FOR MR-GUIDED ASPIRATION CYTOLOGY OF THE HEAD AND NECK [J].
LUFKIN, R ;
TERESI, L ;
HANAFEE, W .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (02) :380-382
[16]  
MICHIE DD, 1975, INVEST UROL, V12, P291
[17]   MR-GUIDED ASPIRATION BIOPSY - NEEDLE DESIGN AND CLINICAL-TRIALS [J].
MUELLER, PR ;
STARK, DD ;
SIMEONE, JF ;
SAINI, S ;
BUTCH, RJ ;
EDELMAN, RR ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1986, 161 (03) :605-609
[18]   Rapid in vivo measurement of single-kidney extraction fraction and glomerular filtration rate with MR imaging [J].
Niendorf, ER ;
Grist, TM ;
Lee, FT ;
Brazy, PC ;
Santyr, GE .
RADIOLOGY, 1998, 206 (03) :791-798
[19]   Intraarterial gadolinium-enhanced 2D and 3D MR angiography: A preliminary study [J].
Omary, RA ;
Frayne, R ;
Unal, O ;
Grist, TM ;
Strother, CM .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (10) :1315-1321
[20]  
OMAWRY RA, 1999, JVIR S, V10, P212