Utility of axillary ultrasound examination to select breast cancer patients suited for optimal sentinel node biopsy

被引:49
作者
Sato, K
Tamaki, K
Tsuda, H
Kosuda, S
Kusano, S
Hiraide, H
Mochizuki, H
机构
[1] Natl Def Med Coll, Dept Surg 1, Tokorozawa, Saitama 3598513, Japan
[2] Natl Def Med Coll, Dept Pathol 2, Tokorozawa, Saitama 3598513, Japan
[3] Natl Def Med Coll, Dept Radiol, Tokorozawa, Saitama 3598513, Japan
[4] Natl Def Med Coll, Inst Res, Tokorozawa, Saitama 3598513, Japan
关键词
axillary ultrasound examination; breast cancer; false-negative result; sentinel node biopsy;
D O I
10.1016/j.amjsurg.2003.10.012
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Because sentinel node (SN) biopsy (SNB) is known to produce false-negative results, we examined the usefulness of axillary ultrasound (AUS) in selecting patients suitable for optimal SNB. Methods: A positive AUS finding (positive AUS) was defined as an echo pattern of a homogeneously hypoechoic SN without an echo-rich center, indicating massive to extensive nodal involvement. The identification of SNs was performed, and complete axillary dissection was carried out. Results: A total of 262 women were enrolled into the study (T1 disease = 94; T2 disease = 145; and T3 disease 23). The incidence of positive AUS increased with increasing size of breast tumor (P < 0.0001). The overall identification and false-negative rates were 88.2% and 10.8%, respectively. However, when limited to AUS-negative patients, SNs were identified in 205 of 208 patients (98.6%), and the false-negative rate was 1.7%. Conclusions: AUS should be included in the preoperative procedure for the selection of breast cancer patients suitable for SNB. (C) 2004 Excerpta Medica, Inc. All rights reserved.
引用
收藏
页码:679 / 683
页数:5
相关论文
共 20 条
[11]  
MUSTONEN P, 1990, ANN CHIR GYNAECOL FE, V79, P15
[12]  
PAMILO M, 1989, J ULTRAS MED, V8, P115
[13]   Ultrasonographically-guided fine-needle aspiration of axillary lymph nodes: role in breast cancer management [J].
Sapino, A ;
Cassoni, P ;
Zanon, E ;
Fraire, F ;
Croce, S ;
Coluccia, C ;
Donadio, M ;
Bussolati, G .
BRITISH JOURNAL OF CANCER, 2003, 88 (05) :702-706
[14]   Efficacy and significance of sentinel lymph node identification with technetium-99m-labeled tin colloids for breast cancer [J].
Sato K. ;
Hiraide H. ;
Uematsu M. ;
Tamaki K. ;
Ishikawa H. ;
Yamasaki T. ;
Tamai S. ;
Kusano S. ;
Mochizuki H. .
Breast Cancer, 1998, 5 (4) :389-393
[15]  
Sato K, 2001, Breast J, V7, P388, DOI 10.1046/j.1524-4741.2001.07602.x
[16]   Clinically useful detection criteria for sentinel nodes in patients with breast cancer using a radioisotope technique [J].
Sato, K ;
Tamaki, K ;
Shigekawa, T ;
Tsuda, H ;
Kosuda, S ;
Kusano, S ;
Hiraide, H ;
Mochizuki, H .
JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2002, 32 (10) :403-406
[17]   Indications and technique of sentinel lymph node biopsy in breast cancer using 99m-technetium labeledtin colloids [J].
Sato K. ;
Uematsu M. ;
Saito T. ;
Ishikawa H. ;
Yamasaki T. ;
Tamaki K. ;
Tamai S. ;
Kusano S. ;
Hiraide H. ;
Mochizuki H. .
Breast Cancer, 2000, 7 (1) :95-98
[18]   COMPLICATIONS AND LOCAL RECURRENCE FOLLOWING LYMPHADENECTOMY [J].
SHAW, JHF ;
RUMBALL, EM .
BRITISH JOURNAL OF SURGERY, 1990, 77 (07) :760-764
[19]  
TATE JJT, 1989, EUR J SURG ONCOL, V15, P139
[20]   IN-VITRO HIGH-RESOLUTION ULTRASONOGRAPHY OF BENIGN AND MALIGNANT LYMPH-NODES - A SONOGRAPHIC-PATHOLOGICAL CORRELATION [J].
VASSALLO, P ;
EDEL, G ;
ROOS, N ;
NAGUIB, A ;
PETERS, PE .
INVESTIGATIVE RADIOLOGY, 1993, 28 (08) :698-705