Double-sided microstrip detectors for the high radiation environment in the HERA-B experiment

被引:8
作者
Abt, I [1 ]
Masciocchi, S [1 ]
Moshous, B [1 ]
Perschke, T [1 ]
Riechmann, K [1 ]
Wagner, W [1 ]
机构
[1] Max Planck Inst Phys, D-80805 Munich, Germany
关键词
D O I
10.1016/S0168-9002(99)00909-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The design of the double-sided microstrip detectors for the HERA-B experiment at DESY is discussed, in particular with respect to the strong requirements imposed by the high radiation environment and by the challenging mechanical construction. The detectors are tested with an infrared laser setup and first results from operation in the experiment in 1997 are presented. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:442 / 450
页数:9
相关论文
共 15 条
[1]   Irradiation tests of double-sided silicon strip detectors with a special guard ring structure [J].
Abt, I ;
Andricek, L ;
Bauer, C ;
Fox, H ;
Halley, A ;
Kroha, H ;
Richter, RH ;
Riechmann, K ;
Rietz, M ;
Rubsam, R ;
Seywerd, H ;
StDenis, R ;
Baumann, I ;
Knopfle, KT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1113-1118
[2]   Single-sided p+n and double-sided silicon strip detectors exposed to fluences up to 2 x 1014/cm2 24 GeV protons [J].
Andricek, L ;
Gebhart, T ;
Hauff, D ;
Kemmer, J ;
Koffeman, E ;
Lutz, G ;
Richter, RH ;
Rohe, T ;
Wunstori, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :184-193
[3]   First experience and results from the HERA-B vertex detector system [J].
Bauer, C ;
Baumann, I ;
Brauer, M ;
Eberle, M ;
Fallot-Burghardt, W ;
Grigoriev, E ;
Hofmann, W ;
Hupper, A ;
Klefenz, F ;
Knopfle, KT ;
Leffers, G ;
Perschke, T ;
Rieling, J ;
Schmelling, M ;
Schwingenheuer, B ;
Sexauer, E ;
Seybold, L ;
Spengler, J ;
StDenis, R ;
Trunk, U ;
Wanke, R ;
Abt, I ;
Fox, H ;
Moshous, B ;
Riechmann, K ;
Rietz, M ;
Ruebsam, R ;
Wagner, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 418 (01) :65-79
[4]   BREAKDOWN PROTECTION AND LONG-TERM STABILIZATION FOR SI-DETECTORS [J].
BISCHOFF, A ;
FINDEIS, N ;
HAUFF, D ;
HOLL, P ;
KEMMER, J ;
KLEIN, P ;
LECHNER, P ;
LUTZ, G ;
RICHTER, RH ;
STRUDER, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :27-37
[5]   Single-sided microstrip detector for high radiation doses [J].
Evensen, L ;
Westgaard, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3) :206-209
[6]  
FALLOTBURGHARDT W, HDASIC330697
[7]  
HARTOUNI E, 9501 DESYPRC
[8]   CONCEPTS FOR SIMPLIFICATION OF STRIP DETECTOR DESIGN AND PRODUCTION [J].
KEMMER, J ;
LUTZ, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 326 (1-2) :209-213
[9]  
LOHSE T, 9402 DESYPRC
[10]  
MOSHOUS B, THESIS TU MUNCHEN