Quantitation and validation of cis-camphoric acid 3-methyl ester and cis-camphoric acid 1-methyl ester using CE

被引:14
作者
Baur, L
Jehle, H
Wätzig, H
机构
[1] Univ Wurzburg, Inst Pharm & Food Chem, D-97074 Wurzburg, Germany
[2] BYK Gulden Lomberg GmbH, Analyt Labs, D-78467 Constance, Germany
关键词
capillary electrophoresis; cis-camphoric acid 1-methyl ester; cis-camphoric acid 3-methyl ester;
D O I
10.1016/S0731-7085(99)00313-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The 1- and 3-methyl esters of cis-camphoric acid, the active agents of a mild laxative (Flubilar(TM)) have been simultaneously assayed using capillary electrophoresis (CE). The compounds are completely separated using a sodium acetate buffer pH 4.0, 40 mmol/l. In order to obtain reproducible results, [+]-naproxen has been used as internal standard (IS). Initially migration times changed over 50% within a series of 20 runs. This problem has been overcome by using an overnight capillary preconditioning (1 mol/l NaOH, 1.5 h) and subsequent equilibrating (running buffer, 12 h). Thereby a precision corresponding to a CV % of about 1.17 and 1.42 for the cia-camphoric acid methyl esters has been obtained (six series of n = 10 runs each). The method has been validated regarding specificity, accuracy, precision, linearity and robustness. In order to test robustness, all key parameters have been considered. The result of the validation is given in nine tables. In the case under investigation, lamp age and wavelength accuracy are the most critical parameters. Therefore, the lamp age should be limited to about 1000 h. The wavelength accuracy can be indirectly controlled using quality assurance samples. According to the fundamental mechanisms in CE, changes in the voltage and in the temperature influence migration times and peak areas. However, these effects are very well compensated using an IS. Slight variations of the parameters buffer pH and molarity rinsing times, storage conditions of buffers and samples as well as the capillary material had little or no influence on the analytical results. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:433 / 449
页数:17
相关论文
共 7 条
[1]  
Altria K. D, 1996, CAPILLARY ELECTROPHO
[2]  
[Anonymous], INT C HARM
[3]  
Baumann K, 1997, PROCESS CONTR QUAL, V10, P59
[4]  
BAUR L, 1998, 11 INT S HIGH PERF C
[5]   Purity control of carbamazepine by micellar electrokinetic chromatography [J].
Degenhardt, M ;
Watzig, H .
JOURNAL OF CHROMATOGRAPHY A, 1997, 768 (01) :113-123
[6]   CHARACTERIZATION OF QUARTZ CAPILLARIES FOR CAPILLARY ELECTROPHORESIS [J].
KOHR, J ;
ENGELHARDT, H .
JOURNAL OF CHROMATOGRAPHY A, 1993, 652 (02) :309-316
[7]   Strategies for capillary electrophoresis:: Method development and validation for pharmaceutical and biological applications [J].
Wätzig, H ;
Degenhardt, M ;
Kunkel, A .
ELECTROPHORESIS, 1998, 19 (16-17) :2695-2752