Construction and performance characterization of ion-selective electrodes for potentiometric determination of phenylpropanolamine hydrochloride applying batch and flow injection analysis techniques

被引:21
作者
Badawy, SS [1 ]
Youssef, AF [1 ]
Mutair, AA [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Giza, Egypt
关键词
phenylpropanolamine hydrochloride; ion-selective electrodes; flow injection analysis; potentiometry;
D O I
10.1016/j.aca.2004.02.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New phenylpropanolamine hydrochloride (PPA.Cl)-selective electrodes of the conventional polymer membrane type, based on incorporation of phenylpropanolamine-tetraphenylborate (PPA-TPB) ion-pair or phenylpropanolamine-phosphotungstate (PPA-PT) ion-associate in a poly(vinyl chloride) (PVC) membrane plasticized with dioctylphethalate (DOP) or dibutylphethalate (DBP), have been constructed. The electrodes were fully characterized in terms of the membrane composition, temperature, and pH. The electrodes were applied to the potentiometric determination of PPA.Cl in pure solutions and in pharmaceutical preparations under batch and flow injection conditions. The sensors showed fast, stable, and Nernstian slope over the concentration ranges 1.0 x 10(-5) to 8.91 x 10(-3) M and 10(-5) to 10(-2) M in the case of PPA-TPB applying batch and flow injection analysis (FIA), respectively, and 5.01 x 10(-6) to 1.25 x 10(-3) M and 10(-5) to 10(-2) M in the case of PPA-PT for batch and FIA systems, respectively. The electrodes exhibited good selectivity for PPA.Cl with respect to a large number of inorganic cations, sugars. amino acids, and components other than phenylpropanol at nine of the mixed drugs. The effect of temperature on the electrodes was also studied. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:207 / 214
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 1998, BRIT PHARMACOPEIA
[2]  
AVDOVICH HV, 1985, J CAN SOC FORENSIC S, V18, P24
[3]   ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF METOCLOPRAMIDE [J].
BADAWY, SS ;
SHOUKRY, AF ;
ISSA, YM .
ANALYST, 1986, 111 (12) :1363-1365
[4]   Electrochemical sensors [J].
Bakker, E ;
Telting-Diaz, M .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2781-2800
[5]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536
[6]  
Cosofret V.V., 1992, PHARM APPL MEMBRANE
[7]   RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58
[8]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MEPYRAMINE MALEATE, PHENIRAMINE MALEATE AND PHENYLPROPANOLAMINE HYDROCHLORIDE IN TABLETS AND DROPS [J].
ELGIZAWY, SM ;
AHMED, AEHN .
ANALYST, 1987, 112 (06) :867-869
[9]   Iron(III)-selective membrane potentiometric sensor based on 5,10,15,20-tetrakis(pentafluorophenyl)-21H, 23H-porphyrin [J].
Fakhari, AR ;
Alaghemand, M ;
Shamsipur, M .
ANALYTICAL LETTERS, 2001, 34 (07) :1097-1106
[10]   Simultaneous spectrophotometric determination of phenilpropanolamine HCL, caffeine and diazepam in tablets [J].
Ferreyra, CF ;
Ortiz, CS .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) :811-818