Measurement of cranial optical path length as a function of age using phase resolved near infrared spectroscopy

被引:381
作者
Duncan, A
Meek, JH
Clemence, M
Elwell, CE
Fallon, P
Tyszczuk, L
Cope, M
Delpy, DT
机构
[1] UNIV LONDON UNIV COLL, RAYNE INST, DEPT PEDIAT, LONDON WC1E 6JJ, ENGLAND
[2] UCL, DEPT MED PHYS & BIOENGN, LONDON WC1E 6JA, ENGLAND
[3] WOLFSON CTR MAGNET TECHNOL, INST CHILD HLTH, NEUROSCI UNIT, LONDON WC1N 2AP, ENGLAND
基金
英国惠康基金;
关键词
D O I
10.1203/00006450-199605000-00025
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Near infrared spectroscopy (NIRS) has been used to measure concentration changes of cerebral hemoglobin and cytochrome in neonates, children, and adults, to study cerebral oxygenation and hemodynamics. To derive quantitative concentration changes from measurements of light attenuation, the optical path length must be known. This is obtained by multiplying the source/ detector separation by a laboratory measured differential path length factor (DPF) which accounts for the increased distance traveled by light due to scattering. DPF has been measured by time of flight techniques on small populations of adults and postmortem infants. The values for adults are greater than those for newborns, and it is not clear how to interpolate the present data for studies on children. Recent developments in instrumentation using phase resolved spectroscopy techniques have produced a bedside unit which can measure optical path length on any subject. We have developed an intensity modulated optical spectrometer which measures path length at four wavelengths. Two hundred and eighty three subjects from 1 d of age to 50 y were studied. Measurements were made at a fixed frequency of 200 MHz and a source detector separation of 4.5 cm. Results suggest a slowly varying age dependence of DPF, following the relation DPF690 = 5.38 + 0.049A(0.877), DPF744 = 5.11 + 0.106A(0.723), DPF807 = 4.99 + 0.067A(0.814), and DPF832 = 4.67 + 0.062A(0.819) where DPF690 is the DPF measured at 690 nm and A is age is expressed in years from full term. There was a wide scatter of values, however, implying that ideally DPF should be measured at the time of each study.
引用
收藏
页码:889 / 894
页数:6
相关论文
共 38 条
[11]  
Delpy D T, 1989, Adv Exp Med Biol, V248, P41
[12]   ESTIMATION OF OPTICAL PATHLENGTH THROUGH TISSUE FROM DIRECT TIME OF FLIGHT MEASUREMENT [J].
DELPY, DT ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, S ;
WRAY, S ;
WYATT, J .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (12) :1433-1442
[13]  
DUNCAN A, 1993, P SOC PHOTO-OPT INS, V1888, P248, DOI 10.1117/12.154641
[14]   OPTICAL PATHLENGTH MEASUREMENTS ON ADULT HEAD, CALF AND FOREARM AND THE HEAD OF THE NEWBORN-INFANT USING PHASE-RESOLVED OPTICAL SPECTROSCOPY [J].
DUNCAN, A ;
MEEK, JH ;
CLEMENCE, M ;
ELWELL, CE ;
TYSZCZUK, L ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (02) :295-304
[15]  
EDWARDS AD, 1988, LANCET, V2, P770
[16]   QUANTIFICATION OF ADULT CEREBRAL HEMODYNAMICS BY NEAR-INFRARED SPECTROSCOPY [J].
ELWELL, CE ;
COPE, M ;
EDWARDS, AD ;
WYATT, JS ;
DELPY, DT ;
REYNOLDS, EOR .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (06) :2753-2760
[17]   SPECTRAL DEPENDENCE OF TEMPORAL POINT SPREAD FUNCTIONS IN HUMAN TISSUES [J].
ESSENPREIS, M ;
ELWELL, CE ;
COPE, M ;
VANDERZEE, P ;
ARRIDGE, SR ;
DELPY, DT .
APPLIED OPTICS, 1993, 32 (04) :418-425
[18]   CEREBRAL HEMODYNAMICS DURING CARDIOPULMONARY BYPASS IN CHILDREN USING NEAR-INFRARED SPECTROSCOPY [J].
FALLON, P ;
ROBERTS, I ;
KIRKHAM, FJ ;
ELLIOTT, MJ ;
LLOYDTHOMAS, A ;
MAYNARD, R ;
EDWARDS, AD .
ANNALS OF THORACIC SURGERY, 1993, 56 (06) :1473-1477
[19]  
FERRARI M, 1993, P SOC PHOTO-OPT INS, V1888, P466, DOI 10.1117/12.154666
[20]  
Ferrari M, 1986, Adv Exp Med Biol, V200, P213