Vascular access ports and catheters: Ex vivo testing of ferromagnetism, heating, and artifacts associated with MR imaging

被引:22
作者
Shellock, FG
Shellock, VJ
机构
[1] Future Diagnostics, Inc., Los Angeles, CA
[2] American Health Services Corporation, Newport Beach, CA
[3] Department of Radiology, University of Southern California, School of Medicine, Los Angeles, CA
[4] Future Diagnostics, Inc., Los Angeles, CA 90048
关键词
magnetic resonance imaging (MRT); safety;
D O I
10.1016/0730-725X(95)02114-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate ferromagnetic qualities, heating, and artifacts associated with MR imaging of implantable vascular access ports (IVAPs, N = 9) and catheters (N = 8). Ferromagnetism was determined using previously described techniques. Heating was assessed for the IVAPs by measuring temperature immediately before and after performing a 3D GRASS, MTC pulse sequence for 60 min at an SAR of 2.8 W/kg. Artifacts were evaluated in association with the use of a fast GRASS pulse sequence and graded according to the severity of image distortion, None of the IVAPs or catheters were attracted by the magnetic field of the MR system, The largest temperature change measured was +0.3 degrees C, Artifacts varied, depending on the component materials used for the construction of the IVAPs and catheters, The lack of ferromagnetic qualities and negligible heating indicates that MR imaging performed at 1.5 T or less may be conducted safely in patients with each of the IVAPs and catheters tested, None of the artifacts produced by the presence of the IVAPs or catheters is considered to impair the diagnostic aspects of MR imaging, especially if the device is not positioned directly in the imaging area of interest.
引用
收藏
页码:443 / 447
页数:5
相关论文
共 10 条
  • [1] MR ARTIFACTS - A REVIEW
    BELLON, EM
    HAACKE, EM
    COLEMAN, PE
    SACCO, DC
    STEIGER, DA
    GANGAROSA, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (06) : 1271 - 1281
  • [2] BOESIGER PB, 1988, MAGNET RESON MED, V7, P255
  • [3] PLACEMENT AND MANAGEMENT OF LONG-TERM CENTRAL VENOUS ACCESS CATHETERS AND PORTS
    DENNY, DF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (02) : 385 - 393
  • [4] SILICONE BREAST IMPLANTS INVIVO - MR IMAGING
    GORCZYCA, DP
    SINHA, S
    AHN, CY
    DEBRUHL, ND
    HAYES, MK
    GAUSCHE, VR
    SHAW, WW
    BASSETT, LW
    [J]. RADIOLOGY, 1992, 185 (02) : 407 - 410
  • [5] IMPORTANT CONSIDERATIONS IN MEASUREMENT OF ATTRACTIVE FORCE ON METALLIC IMPLANTS IN MR IMAGERS
    KAGETSU, NJ
    LITT, AW
    [J]. RADIOLOGY, 1991, 179 (02) : 505 - 508
  • [6] POTENTIAL HAZARDS AND ARTIFACTS OF FERROMAGNETIC AND NONFERROMAGNETIC SURGICAL AND DENTAL MATERIALS AND DEVICES IN NUCLEAR MAGNETIC-RESONANCE IMAGING
    NEW, PFJ
    ROSEN, BR
    BRADY, TJ
    BUONANNO, FS
    KISTLER, JP
    BURT, CT
    HINSHAW, WS
    NEWHOUSE, JH
    POHOST, GM
    TAVERAS, JM
    [J]. RADIOLOGY, 1983, 147 (01) : 139 - 148
  • [7] EX-VIVO EVALUATION OF FERROMAGNETISM, HEATING, AND ARTIFACTS PRODUCED BY HEART-VALVE PROSTHESES EXPOSED TO A 1.5-T MR SYSTEM
    SHELLOCK, FG
    MORISOLI, SM
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) : 756 - 758
  • [8] SHELLOCK FG, 1991, AM J NEURORADIOL, V12, P279
  • [9] SHELLOCK FG, 1994, MAGNETIC RESONANCE B
  • [10] SHELLOCK FG, 1996, POCKET GUIDE MR PROC