Repeatability and reproducibility of retention data and band profiles on reversed-phase liquid chromatography columns -: IV.: Results obtained with luna C18 (2) columns

被引:68
作者
Kele, M
Guiochon, G [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
关键词
band profiles; luna C-18 (2); stationary phases; LC; retention data;
D O I
10.1016/S0021-9673(99)01092-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The reproducibility of retention data and band profile characteristics was investigated for a series of columns packed with Luna C-18 (2), a silica-based, reversed-phase adsorbent. High precision data were obtained and statistically compared among five columns from the same batch (column-to-column reproducibility) and nine columns from as many different batches (batch-to-batch reproducibility). These data were acquired under five different sets of chromatographic conditions, for a group of 30 neutral, acidic, and basic compounds selected as probes following an experimental protocol previously described. This work is part of a study on the precision of chromatographic analyses. Its purpose is to illustrate the contribution of the stationary phase reproducibility to this precision. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 209
页数:29
相关论文
共 29 条
  • [1] Characterization of silica-based octyl phases of different bonding density - Part I. Thermal stability studies
    Bereznitski, Y
    Jaroniec, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 51 - 58
  • [2] Comparative characterization of octyl bonded phases using methylene selectivity data
    Bhagwat, V
    Bereznitski, Y
    Buszewski, B
    Jaroniec, M
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (07) : 923 - 939
  • [3] Evaluation procedures for reversed-phase high-performance liquid chromatographic columns in the analysis of strongly basic compounds using principal components analysis for data assessment
    Brereton, RG
    McCalley, DV
    [J]. ANALYST, 1998, 123 (06) : 1175 - 1185
  • [4] Comparative study of test methods for reversed-phase columns for high-performance liquid chromatography
    Claessens, HA
    van Straten, MA
    Cramers, CA
    Jezierska, M
    Buszewski, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 826 (02) : 135 - 156
  • [5] CHROMATOGRAPHIC CHARACTERIZATION OF SILICA-BASED REVERSED PHASES
    ENGELHARDT, H
    LOW, H
    GOTZINGER, W
    [J]. JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2): : 371 - 379
  • [6] Chromatographic determination of metallic impurities in reversed-phase HPLC columns
    Engelhardt, H
    Lobert, T
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (09) : 1885 - 1892
  • [7] Engelhardt H, 1997, LC GC-MAG SEP SCI, V15, P856
  • [8] COMPARISON AND CHARACTERIZATION OF REVERSED PHASES
    ENGELHARDT, H
    JUNGHEIM, M
    [J]. CHROMATOGRAPHIA, 1990, 29 (1-2) : 59 - 68
  • [9] Studies on shape selectivity of RP C18-columns
    Engelhardt, H
    Nikolov, M
    Arangio, M
    Scherer, M
    [J]. CHROMATOGRAPHIA, 1998, 48 (3-4) : 183 - 189
  • [10] Guiochon G., 1994, FUNDAMENTALS PREPARA