Development of standard tests to examine viscoelastic properties of blood of experimental animals for pediatric mechanical support device evaluation

被引:18
作者
Marascalco, Philip J.
Ritchie, Sean P.
Snyder, Trevor A.
Kameneva, Marina V.
机构
[1] Univ Pittsburgh, McGowan Inst Regenerat Med, Pittsburgh, PA 15219 USA
[2] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA 15219 USA
[3] Univ Pittsburgh, Dept Surg, Pittsburgh, PA 15219 USA
关键词
HYPOTHERMIC CARDIOPULMONARY BYPASS; FLUID-DYNAMICS; ERYTHROCYTE DEFORMABILITY; CELL DEFORMABILITY; PLASMA VISCOSITY; ASSIST DEVICE; SHEAR RATE; RED-CELL; FLOW; PUMP;
D O I
10.1097/01.mat.0000242248.66083.48
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
We investigated the applicability of measuring the viscoelasticity of bovine, ovine, and porcine whole blood for the evaluation of sublethal damage to red blood cells (RBCs). An increase in blood viscosity and elasticity without changes in hematocrit and plasma viscosity would signify a decrease in RBC deformability. Blood viscoelasticity was assessed using a Vilastic Scientific viscoelastometer. Due to the natural absence of RBC aggregation and small RBC size in normal bovine and ovine blood, viscoelastic properties are less readily detected. However, we found that adjustment of blood hematocrit to a standard level of 40-50% allows for sensitive assessment of viscoelasticity in these blood types demonstrating a marked non-Newtonian behavior mostly related to RBC deformability. Porcine blood showed a pronounced non-Newtonian behavior at all tested hematocrit values, which makes it rheologically comparable to human blood. Both viscosity and elasticity were elevated after blood exposure to a uniform mechanical stress. RBCs rigidified by heat exposure demonstrated a loss of viscoelasticity dependence on shear rate. Measurements of blood viscoelasticity can be meaningful in bovine, ovine, and, especially, porcine blood, and can be used for evaluation of sublethal blood damage during in vitro and animal trials of heart-assist devices.
引用
收藏
页码:567 / 574
页数:8
相关论文
共 61 条
[1]
A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump [J].
Arvand, A ;
Hormes, M ;
Reul, H .
ARTIFICIAL ORGANS, 2005, 29 (07) :531-540
[2]
The national heart, lung, and blood institute pediatric circulatory support program [J].
Baldwin, JT ;
Borovetz, HS ;
Duncan, BW ;
Gartner, MJ ;
Jarvik, RK ;
Weiss, WJ ;
Hoke, TR .
CIRCULATION, 2006, 113 (01) :147-155
[3]
BARBEE JH, 1973, BIORHEOLOGY, V10
[4]
BEGG TB, 1966, CLIN SCI, V31, P87
[5]
Research approaches for studying flow-induced thromboembolic complications in blood recirculating devices [J].
Bluestein, D .
EXPERT REVIEW OF MEDICAL DEVICES, 2004, 1 (01) :65-80
[6]
BOHLER T, 1992, PEDIATR RES, V32, P92
[7]
BRINSFIELD DE, 1962, J APPL PHYS, V17, P531
[8]
INTERACTIONS AMONG ERYTHROCYTES UNDER SHEAR [J].
BROOKS, DE ;
GOODWIN, JW ;
SEAMAN, GVF .
JOURNAL OF APPLIED PHYSIOLOGY, 1970, 28 (02) :172-&
[9]
BROOKSHIER KK, 1991, BIORHEOLOGY, V28, P569
[10]
SHEAR-DEPENDENT DEFORMATION OF ERYTHROCYTES IN RHEOLOGY OF HUMAN BLOOD [J].
CHIEN, S ;
USAMI, S ;
DELLENBACK, RJ ;
GREGERSEN, MI .
AMERICAN JOURNAL OF PHYSIOLOGY, 1970, 219 (01) :136-+