Determination of carbon labeling distribution of intracellular metabolites from single fragment ions by ion chromatography tandem mass spectrometry

被引:64
作者
Kiefer, Patrick [1 ]
Nicolas, Cecile [1 ]
Letisse, Fabien [1 ]
Portais, Jean-Charles [1 ]
机构
[1] INRA, CNRS 5504, UMR INSA 792, Lab Biotechnol Bioprocedes, F-31077 Toulouse, France
关键词
C-13 labeling analysis; mass isotopomer analysis; liquid chromatography electrospray ionization tandem mass spectrometry; central metabolism;
D O I
10.1016/j.ab.2006.06.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography tandem mass spectrometry coupling is a highly sensitive and specific technique allowing molecule detection in the fermomolar range. This article introduces a straightforward approach to apply this technique in C-13 metabolic flux analysis. Based on a theoretical analysis of the correlation between molecule ions and corresponding fragments, a method was developed to determine the carbon labeling of intracellular metabolites without increasing the number of measurements per metabolite compared with direct molecule ion analysis. The method was applied to phosphorylated metabolites because their fragmentation results in high yields of [PO3](-) and/or [H2PO4](-) ions. Comparing the accuracy of the carbon labeling determination of phosphorylated metabolites between direct analysis of the molecule ions with that of corresponding phosphate fragment ions, it could be demonstrated that the introduced approach resulted in significantly higher accuracy and sensitivity for all tested metabolites. When applying the techniques to Escherichia coli cell extracts, 2 mu g cell dry weight per injection was sufficient to determine the natural abundances of the carbon fractions in and in + I from six phosphorylated metabolites with high accuracy, predestining the approach for very small cultivation volumes in the microliter range. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 10 条
[1]   GC-MS analysis of amino acids rapidly provides rich information for isotopomer balancing [J].
Dauner, M ;
Sauer, U .
BIOTECHNOLOGY PROGRESS, 2000, 16 (04) :642-649
[2]   Improved protocols for quantitative determination of metabolites from biological samples using high performance ionic-exchange chromatography with conductimetric and pulsed amperometric detection [J].
Groussac, E ;
Ortiz, M ;
François, J .
ENZYME AND MICROBIAL TECHNOLOGY, 2000, 26 (9-10) :715-723
[3]   Comparative metabolic flux analysis of lysine-producing Corynebacterium glutamicum cultured on glucose, or fructose [J].
Kiefer, P ;
Heinzle, E ;
Zelder, O ;
Wittmann, C .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (01) :229-239
[4]   MIRACLE:: mass isotopomer ratio analysis of U-13C-labeled extracts.: A new method for accurate quantification of changes in concentrations of intracellular metabolites [J].
Mashego, MR ;
Wu, L ;
Van Dam, JC ;
Ras, C ;
Vinke, JL ;
Van Winden, WA ;
Van Gulik, WM ;
Heijnen, JJ .
BIOTECHNOLOGY AND BIOENGINEERING, 2004, 85 (06) :620-628
[5]   METABOLIC FLUX DETERMINATION IN C6 GLIOMA-CELLS USING C-13 DISTRIBUTION UPON [1-C-13]GLUCOSE INCUBATION [J].
PORTAIS, JC ;
SCHUSTER, R ;
MERLE, M ;
CANIONI, P .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1993, 217 (01) :457-468
[6]   Analysis of glycolytic intermediates in Saccharomyces cerevisiae using anion exchange chromatography and electrospray ionization with tandem mass spectrometric detection [J].
van Dam, JC ;
Eman, MR ;
Frank, J ;
Lange, HC ;
van Dedem, GWK ;
Heijnen, SJ .
ANALYTICA CHIMICA ACTA, 2002, 460 (02) :209-218
[7]   Metabolic-flux analysis of Saccharomyces cerevisiae CEN.PK113-7D based on mass isotopomer measurements of 13C-labeled primary metabolites [J].
van Winden, WA ;
van Dam, JC ;
Ras, C ;
Kleijn, RJ ;
Vinke, JL ;
van Gulik, WM ;
Heijnen, JJ .
FEMS YEAST RESEARCH, 2005, 5 (6-7) :559-568
[8]   Correcting mass isotopomer distributions for naturally occurring isotopes [J].
van Winden, WA ;
Wittmann, C ;
Heinzle, E ;
Heijnen, JJ .
BIOTECHNOLOGY AND BIOENGINEERING, 2002, 80 (04) :477-479
[9]   Impact of the cold shock phenomenon on quantification of intracellular metabolites in bacteria [J].
Wittmann, C ;
Krömer, JO ;
Kiefer, P ;
Binz, T ;
Heinzle, E .
ANALYTICAL BIOCHEMISTRY, 2004, 327 (01) :135-139
[10]   In vivo analysis of intracellular amino acid labelings by GUMS [J].
Wittmann, C ;
Hans, M ;
Heinzle, E .
ANALYTICAL BIOCHEMISTRY, 2002, 307 (02) :379-382