Motion artifacts in optical coherence tomography with frequency-domain ranging

被引:274
作者
Yun, SH
Tearney, GJ
de Boer, JF
Bouma, BE
机构
[1] Harvard Univ, Sch Med, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2004年 / 12卷 / 13期
关键词
D O I
10.1364/OPEX.12.002977
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe results of theoretical and experimental investigations of artifacts that can arise in spectral-domain optical coherence tomography (SD-OCT) and optical frequency domain imaging (OFDI) as a result of sample or probe beam motion. While SD-OCT and OFDI are based on similar spectral interferometric principles, the specifics of motion effects are quite different because of distinct signal acquisition methods. These results provide an understanding of motion artifacts such as signal fading, spatial distortion and blurring, and emphasize the need for fast image acquisition in biomedical applications. (C) 2004 Optical Society of America.
引用
收藏
页码:2977 / 2998
页数:22
相关论文
共 32 条
[1]   EFFECTS OF BIOLOGICAL MOTION ON CT RESOLUTION [J].
ALFIDI, RJ ;
MACINTYRE, WJ ;
HAAGA, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1976, 127 (01) :11-15
[2]  
BANKMAN N, 2000, HDB MED IMAGING
[3]   HIGH-RESOLUTION OCDR IN DISPERSIVE WAVE-GUIDES [J].
BRINKMEYER, E ;
ULRICH, R .
ELECTRONICS LETTERS, 1990, 26 (06) :413-414
[4]   Optical coherence tomography using a frequency-tunable optical source [J].
Chinn, SR ;
Swanson, EA ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (05) :340-342
[5]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[6]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[7]   OPTICAL FREQUENCY-DOMAIN REFLECTOMETRY IN SINGLE-MODE FIBER [J].
EICKHOFF, W ;
ULRICH, R .
APPLIED PHYSICS LETTERS, 1981, 39 (09) :693-695
[8]   MEASUREMENT OF INTRAOCULAR DISTANCES BY BACKSCATTERING SPECTRAL INTERFEROMETRY [J].
FERCHER, AF ;
HITZENBERGER, CK ;
KAMP, G ;
ELZAIAT, SY .
OPTICS COMMUNICATIONS, 1995, 117 (1-2) :43-48
[9]   OPTICAL BIOPSY AND IMAGING USING OPTICAL COHERENCE TOMOGRAPHY [J].
FUJIMOTO, JG ;
BREZINSKI, ME ;
TEARNEY, GJ ;
BOPPART, SA ;
BOUMA, B ;
HEE, MR ;
SOUTHERN, JF ;
SWANSON, EA .
NATURE MEDICINE, 1995, 1 (09) :970-972
[10]   Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+:forsterite laser [J].
Golubovic, B ;
Bouma, BE ;
Tearney, GJ ;
Fujimoto, JG .
OPTICS LETTERS, 1997, 22 (22) :1704-1706