Amperometric biosensor based on carbon nanotubes coated with polyaniline/dendrimer-encapsulated Pt nanoparticles for glucose detection

被引:59
作者
Xu, Lihuan [1 ]
Zhu, Yihua [1 ]
Yang, Xiaoling [1 ]
Li, Chunzhong [1 ]
机构
[1] E China Univ Sci & Technol, Key Lab Ultrafine Mat, Minist Educ, Sch Mat Sci & Engn, Shanghai 200237, Peoples R China
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2009年 / 29卷 / 04期
基金
中国国家自然科学基金;
关键词
Carbon nanotubes; Polyaniline; Glucose oxidase; Dendrimer-encapsulated nanoparticles; Biosensor; GOLD NANOPARTICLES; MODIFIED ELECTRODE; PLATINUM; OXIDASE;
D O I
10.1016/j.msec.2008.10.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A novel amperometric glucose biosensor based on the nanocomposites of multi-wall carbon nanotubes (CNT) coated with polyaniline (PANI) and dendrimer-encapsulated Pt nanoparticles (Pt-DENs) is prepared. CNT coated with protonated PANI is in situ synthesized and Pt-DENs is absorbed on PANI/CNT composite surface by self-assembly method. Then Glucose oxidase (GOx) is crosslink-immobilizated onto Pt-DENs/PANI/CNT composite film. The results show that the fabricated GOx/Pt-DENs/PANI/CNT electrode exhibits excellent response performance to glucose, such as low detection limit (0.5 mu M), wide linear range (1 mu M-12 mM), short response time (about 5 s), high sensitivity (42.0 mu A mM(-1) cm(-2)) and stability (83% remains after 3 weeks). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1306 / 1310
页数:5
相关论文
共 29 条
[11]   SWNTs coated by conducting polyaniline: Synthesis and modified properties [J].
Karim, MR ;
Lee, CJ ;
Park, YT ;
Lee, MS .
SYNTHETIC METALS, 2005, 151 (02) :131-135
[12]  
LAO X, 2006, ANAL CHIM ACTA, V575, P39
[13]   A glucose biosensor based on electrodeposition of palladium nanoparticles and glucose oxidase onto Nafion-solubilized carbon nanotube electrode [J].
Lim, SH ;
Wei, J ;
Lin, JY ;
Li, QT ;
KuaYou, J .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (11) :2341-2346
[14]   In neutral solution and their application for stable low-potential detection of reduced β-nicotinamide adenine dinucleotide [J].
Liu, JY ;
Tian, SJ ;
Knoll, W .
LANGMUIR, 2005, 21 (12) :5596-5599
[15]   Method for supporting platinum on single-walled carbon nanotubes for a selective hydrogenation catalyst [J].
Lordi, V ;
Yao, N ;
Wei, J .
CHEMISTRY OF MATERIALS, 2001, 13 (03) :733-737
[16]   APPLICATION OF CARBON NANOTUBES AS SUPPORTS IN HETEROGENEOUS CATALYSIS [J].
PLANEIX, JM ;
COUSTEL, N ;
COQ, B ;
BROTONS, V ;
KUMBHAR, PS ;
DUTARTRE, R ;
GENESTE, P ;
BERNIER, P ;
AJAYAN, PM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (17) :7935-7936
[17]   Fabrication of a new polyaniline grafted multi-wall carbon nanotube modified electrode and its application for electrochemical detection of hydrogen peroxide [J].
Santhosh, P. ;
Manesh, K. M. ;
Gopalan, A. ;
Lee, Kwang-Pill .
ANALYTICA CHIMICA ACTA, 2006, 575 (01) :32-38
[18]   Gold nanoparticles dispersed polyaniline grafted multiwall carbon nanotubes as newer electrocatalysts: Preparation and performances for methanol oxidation [J].
Santhosh, P ;
Gopalan, A ;
Lee, KP .
JOURNAL OF CATALYSIS, 2006, 238 (01) :177-185
[19]   Preparation and characterization of composites of polyaniline nanorods and multiwalled carbon nanotubes coated with polyaniline [J].
Su, Chang ;
Wang, Gengchao ;
Huang, Farong .
JOURNAL OF APPLIED POLYMER SCIENCE, 2007, 106 (06) :4241-4247
[20]   Carbon-nanotube based electrochemical biosensors: A review [J].
Wang, J .