Performance improvement of gas turbine power plants by utilizing turbine inlet air-cooling (TIAC) technologies in Riyadh, Saudi Arabia

被引:56
作者
Baakeem, Saleh S. [1 ]
Orfi, Jamel [1 ]
Al-Ansary, Hany [1 ]
机构
[1] King Saud Univ, Mech Engn Dept, POB 800, Riyadh 11421, Saudi Arabia
关键词
Gas turbine; Single turbine inlet air-cooling (TIAC) technologies; Power boosting; Economic analysis; RECOVERY STEAM-GENERATOR; WASTE-HEAT-RECOVERY; COMBINED-CYCLE; MULTIOBJECTIVE OPTIMIZATION; THERMODYNAMIC ASSESSMENT; THERMOECONOMIC ANALYSIS; AMBIENT-TEMPERATURE; ENERGY; ENHANCEMENT; SYSTEM;
D O I
10.1016/j.applthermaleng.2018.04.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
Gas turbine performance is very sensitive to the ambient air conditions, particularly in hot and arid climates. Various turbine inlet air cooling (TIAC) techniques including mechanical vapor compression and lithium bromide-water absorption refrigeration systems are used in several locations worldwide. This work concerns a comparative study using mass and energy balances and cost analysis of several cooling technologies coupled with a typical gas turbine under Riyadh weather conditions. The results are expressed in terms of yearly variations of power output, fuel consumption, and thermal efficiency of the gas turbine unit. They also include the total and operating costs and the payback period for each configuration of TIAC systems. The study proposes first systematic approaches to determine the air cooled temperature at the compressor inlet and the corresponding cooling capacity for the considered TIAC systems. The optimum values of such air cooled temperature and cooling capacity are found to be 8 degrees C and 36 kW/m(3) s(-1), respectively. The comparative study shows that using the media evaporative cooling, the simple mechanical vapor compression or the single-effect H2O-NH3 absorption cooling systems are not recommended. However, the sub-cooling multistage compressor system coupled with a wet cooled condenser and the single-effect LiBr-H2O-absorption refrigeration systems show better performance.
引用
收藏
页码:417 / 432
页数:16
相关论文
共 81 条
[1]   Impact of the use of a hybrid turbine inlet air cooling system in arid climates [J].
Al-Ansary, Hany A. ;
Orfi, Jamel A. ;
Ali, Mohamed E. .
ENERGY CONVERSION AND MANAGEMENT, 2013, 75 :214-223
[2]   The effect of elevated inlet air temperature and relative humidity on cogeneration system [J].
Al-Fahed, S. F. ;
Alasfour, F. N. ;
Abdulrahim, H. K. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2009, 33 (15) :1384-1394
[3]   A review of inlet air-cooling technologies for enhancing the performance of combustion turbines in Saudi Arabia [J].
Al-Ibrahim, Abdulrahman M. ;
Varnham, Abdulhadi .
APPLIED THERMAL ENGINEERING, 2010, 30 (14-15) :1879-1888
[4]   Performance enhancement of gas turbines by inlet air-cooling in hot and humid climates [J].
Alhazmy, Majed M. ;
Jassim, Rahim K. ;
Zaki, Galal M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (10) :777-797
[5]   Augmentation of gas turbine performance using air coolers [J].
Alhazmy, MM ;
Najjar, YSH .
APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) :415-429
[6]   Performance and economic of the thermal energy storage systems to enhance the peaking capacity of the cas turbines [J].
Ameri, M ;
Hejazi, SH ;
Montaser, K .
APPLIED THERMAL ENGINEERING, 2005, 25 (2-3) :241-251
[7]   The study of capacity enhancement of the Chabahar gas turbine installation using an absorption chiller [J].
Ameri, M ;
Hejazi, SH .
APPLIED THERMAL ENGINEERING, 2004, 24 (01) :59-68
[8]  
[Anonymous], ANN REP
[9]  
[Anonymous], 1999, 421 WORLD BANK
[10]  
[Anonymous], ANN REP