In-flight validation and routine measurements

被引:20
作者
Beck, P [1 ]
Bartlett, D
O'Brien, K
Schrewe, UJ
机构
[1] Austrian Res Ctr, A-2444 Seibersdorf, Austria
[2] Natl Radiol Protect Board, Didcot OX11 0RQ, Oxon, England
[3] No Arizona Univ, Flagstaff, AZ 86011 USA
[4] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
关键词
D O I
10.1093/oxfordjournals.rpd.a032962
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Different methods of aircrew dose assessment are under discussion and evaluation by several international research groups. The TEPC (tissue-equivalent proportional counter) has been used very successfully to describe the radiation field during in-flight measurements. Cosmic ray transport calculations of effective dose have been compared with TEPC measurements, with good results. Several active conventional photon and neutron detectors, as well as a passive dosemeter, have been prepared and characterised for in-flight radiation measurements. A novel method, combining measurements with a conventional radiation detector and results of cosmic ray transport calculations is at present under evaluation in the European research project ACREM (Air Crew Radiation Monitor). Superimposed on the regular and more-or-less predictable eleven year cosmic ray intensity variation, events on the sun will occasionally result in high energy particle fluxes that will impact on the tellurian atmosphere and result in unforeseen high additional radiation exposures. Appropriate methods to determine the resulting radiation dose rates will be described.
引用
收藏
页码:303 / 308
页数:6
相关论文
共 19 条
[1]   Prostate cancer in the popular press [J].
Bartha, R ;
Altwein, JE .
AKTUELLE UROLOGIE, 1997, 28 (01) :1-3
[2]   Radiation protection concepts and quantities for the occupational exposure to cosmic radiation [J].
Bartlett, DT .
RADIATION PROTECTION DOSIMETRY, 1999, 86 (04) :263-268
[3]  
BECK P, 1998, OEFZSA4317
[4]  
BECK P, 1997, P IRPA C 8 12 SEPT 1, P76
[5]  
DUFTSCHMID KE, 1994, OEFZS4717
[6]   Operation and application of tissue-equivalent proportional counters [J].
Gerdung, S ;
Pihet, P ;
Grindborg, JE ;
Roos, H ;
Schrewe, UJ ;
Schuhmacher, H .
RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) :381-404
[7]  
*GERM COMM RAD PRO, 1998, DET AIR CREW RAD EXP, pA1
[8]   Physics of cosmic radiation fields [J].
Heinrich, W ;
Roesler, S ;
Schraube, H .
RADIATION PROTECTION DOSIMETRY, 1999, 86 (04) :253-258
[9]  
*INT COMM RAD PROT, 1991, PUBL INT COMM RAD PR, V60
[10]   The use of TEPC for reference dosimetry [J].
Lindborg, L ;
Kyllönen, JE ;
Beck, P ;
Bottollier-Depois, JF ;
Gerdung, S ;
Grillmaier, RE ;
Schrewe, U .
RADIATION PROTECTION DOSIMETRY, 1999, 86 (04) :285-288