Particle deposition and decay in a chamber and the implications to exposure assessment

被引:10
作者
Lai, Alvin C. K. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
particulate matter; deposition; inhalation transfer factor; exposure risk assessment; indoor air quality;
D O I
10.1007/s11270-006-9141-y
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate modeling indoor aerosol deposition and decay is an important step for exposure assessment. High deposition rate reduces indoor pollutant concentration and results in lower inhalation exposure. Many of indoor surfaces have random roughness protrusion scales up to several millimeters which it may significantly affect the deposition loss rate. Aerosols deposition onto most indoor surfaces can be considered as "rough' surface deposition. However, particle deposition from anleaflong indoor environment is frequently modeled by assuming that surfaces are smooth. In this work, experimental results for deposition velocity onto drywall surfaces for supermicron particles from 1 to 7 mu m are presented. Deposition velocity is significantly higher than that predicted by a previous published model. To illustrative the influence of particle deposition on exposure, two hypothetical room sizes and two air exchange rates were considered. Inhalation transfer factor was adopted as a risk exposure index. Taking into account of high deposition velocity onto drywall surfaces, inhalation transfer factors are 8 to 35% lower than that predicted by the model and this significant difference is important to the exposure assessment.
引用
收藏
页码:323 / 334
页数:12
相关论文
共 24 条
[1]   Indoor particle pollution: effect of wall textures on particle deposition [J].
Abadie, M ;
Limam, K ;
Allard, F .
BUILDING AND ENVIRONMENT, 2001, 36 (07) :821-827
[2]  
[Anonymous], [No title captured]
[3]   Defining intake fraction [J].
Bennett, DH ;
McKone, TE ;
Evans, JS ;
Nazaroff, WW ;
Margni, MD ;
Jolliet, O ;
Smith, KR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (09) :206A-211A
[4]   Modeling particle distribution and deposition in indoor environments with a new drift-flux model [J].
Chen, FZ ;
Yu, SCM ;
Lai, ACK .
ATMOSPHERIC ENVIRONMENT, 2006, 40 (02) :357-367
[5]   Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios [J].
Fogh, CL ;
Byrne, MA ;
Roed, J ;
Goddard, AJH .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (15) :2193-2203
[6]   Modeling indoor air concentrations near emission sources in imperfectly mixed rooms [J].
Furtaw, EJ ;
Pandian, MD ;
Nelson, DR ;
Behar, JV .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (09) :861-868
[7]   Indoor pollutant mixing time in an isothermal closed room: an investigation using CFD [J].
Gadgil, AJ ;
Lobscheid, C ;
Abadie, MO ;
Finlayson, EU .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (39-40) :5577-5586
[8]  
Hinds W.C., 1998, AEROSOL TECHNOLOGY, VSecond
[9]   Indoor and outdoor particle size characterization at a family house in Espoo-Finland [J].
Hussein, T ;
Hämeri, K ;
Heikkinen, MSA ;
Kulmala, M .
ATMOSPHERIC ENVIRONMENT, 2005, 39 (20) :3697-3709
[10]   Inhalation transfer factors for air pollution health risk assessment [J].
Lai, ACK ;
Thatcher, TL ;
Nazaroff, WW .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (09) :1688-1699