CsI(Na), CsI(Tl) and NaI(Tl) scintillators coupled through optical fibers were investigated with simulations and measurements to evaluate their potential as gamma imaging intraoperative probes. Three coupling methods were employed: discrete crystals coupled one-to-one with the fibers; discrete crystals coupled through a light diffuser to an unmatched fiber array; and continuous crystals coupled directly to the fiber optic array. The discrete crystals were 4x4 element arrays ranging in size from 1x1x2.5 mm(3) to 2x2x6 mm(3). CsI(Na) produced the best pulse height and single crystal energy resolution (44% at 140 keV) when coupled through fibers to the photodetector. All elements of the arrays were completely resolved, indicating that the intrinsic spatial resolution will be determined by the crystal size. The spatial resolution for the 12.5 mm phi x 3.5 mm continuous crystals was similar to 1.33 mm FWHM. Preliminary imaging measurements faithfully reproduced the activity distributions and compared favorably with simulations.
引用
收藏
页码:1254 / 1261
页数:8
相关论文
共 28 条
[1]   EFFECT OF THE EXTENT OF SURGICAL RESECTION ON SURVIVAL AND QUALITY-OF-LIFE IN PATIENTS WITH SUPRATENTORIAL GLIOBLASTOMAS AND ANAPLASTIC ASTROCYTOMAS [J].
AMMIRATI, M ;
VICK, N ;
LIAO, Y ;
CIRIC, I ;
MIKHAEL, M .
NEUROSURGERY, 1987, 21 (02) :201-206
[2]  
BAILLET G, 1994, EUR J NUCL MED, V21, P1061
[3]  
BARRETT HH, 1981, RAIDOLOGICAL IMAGING, V1, pCH5
[4]   THE OPTIMIZATION OF SMALL CSI(TL) GAMMA-RAY DETECTORS [J].
BIRD, AJ ;
CARTER, T ;
DEAN, AJ ;
RAMSDEN, D ;
SWINYARD, BM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :395-399
[5]   CHARGE-DIVISION MULTIPLEXING CIRCUITS FOR LOW-ENERGY GAMMA-RAY DETECTION - THEORY AND EXPERIMENTATION [J].
BLOYET, D ;
LEPAISANT, J ;
CAHAN, B ;
GUTKNECHT, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (02) :315-322
[6]   A COMPARISON OF PET DETECTOR MODULES EMPLOYING RECTANGULAR AND ROUND PHOTOMULTIPLIER TUBES [J].
CHERRY, SR ;
TORNAI, MP ;
LEVIN, CS ;
SIEGEL, S ;
HOFFMAN, EJ ;
ANDREACO, MS ;
WILLIAMS, CW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1064-1068
[7]   COLLECTION OF SCINTILLATION LIGHT FROM SMALL BGO CRYSTALS [J].
CHERRY, SR ;
SHAO, YP ;
TORNAI, MP ;
SIEGEL, S ;
RICCI, AR ;
PHELPS, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :1058-1063
[8]   USE OF DIGITAL FRONT-END ELECTRONICS FOR OPTIMIZATION OF A MODULAR PET DETECTOR [J].
CUTLER, PD ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (02) :408-418
[9]  
Daghighian F, 1996, J NUCL MED, V37, pS29
[10]   AN EVALUATION OF A TWO-DIMENSIONAL ARRAY DETECTOR FOR HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :264-272