Trace level quantification of deuterated 17β-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction

被引:33
作者
Xia, YQ [1 ]
Chang, SW [1 ]
Patel, S [1 ]
Bakhtiar, R [1 ]
Karanam, B [1 ]
Evans, DC [1 ]
机构
[1] Merck Res Labs, Dept Drug Metab, Rahway, NJ 07065 USA
关键词
D O I
10.1002/rcm.1530
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with dansylation was developed for the simultaneous quantification of exogenously administered deuterated 17beta-estradiol-d(4) (E2-d(4)) and its metabolite, estrone-d(4) (E1-d(4)), in mouse plasma and brain homogenates. The dansylation reaction was simple, fast, and sensitive, and a lower limit of quantification of 50 pg/mL was achieved by using 50 muL of mouse plasma. Interference from endogenous 17beta-estradiol and estrone in plasma and brain samples was minimized by the use of deuterated-E2 as well by utilizing ovariectomized (OVX) mice. The recovery of dansylated derivative exceeded 83% and the reaction was completed within approximately 3 min. The intra- and inter-day assay precision were better than 12.9% and assay accuracy ranged between 92-104% for E1-d(4) and E2-d(4) in plasma, respectively. The absorption of E2-d(4) at both 1 and 3 mg/kg P.O. was rapid, reaching peak plasma concentrations (C-max) at 5 min post-dose that was the earliest time point obtained, and were 1.1 and 13.8 ng/mL, respectively; the C-max values for the estrone metabolite, E1-d(4), were 1.1 and 43.2 ng/mL, respectively. The area-under-the-plasma-time curve (AUC(0-2h)) values were determined to be 0.65 and 2.90 ng (.) h/mL for E2-d(4) and 0.77 and 6.74 ng (.) h/mL for E1-d(4), respectively, at 1 and 3 mg/kg. The mean brain-to-plasma ratio for E1-d(4) and E2-d(4) after P.O. administration of E2-d(4) to the OVX mice at 1 and 3 mg/kg indicated that both E1-d(4) and E2-d(4) were present in the brain as well as in the circulation. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1621 / 1628
页数:8
相关论文
共 23 条
[1]   Derivatization of ethinylestradiol with dansyl chloride to enhance electrospray ionization: Application in trace analysis of ethinylestradiol in rhesus monkey plasma [J].
Anari, MR ;
Bakhtiar, R ;
Zhu, B ;
Huskey, S ;
Franklin, RB ;
Evans, DC .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4136-4144
[2]  
AWAIN IH, 1999, ENDOCRINOLOGY, V140, P3843
[3]   Analysis of multiple endocrine disruptors in environmental waters via wide-spectrum solid-phase extraction and dual-polarity ionization LC-ion trap-MS/MS [J].
Benijts, T ;
Lambert, W ;
De Leenheer, A .
ANALYTICAL CHEMISTRY, 2004, 76 (03) :704-711
[4]   Determination of 17β-estradiol in bovine plasma:: development of a highly sensitive technique by ion trap gas chromatography-tandem mass spectrometry using negative chemical ionization [J].
Biancotto, G ;
Angeletti, R ;
Traldi, P ;
Silvestri, M ;
Saccon, M ;
Guidugli, F .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (12) :1266-1271
[5]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.3.CO
[6]  
2-S
[7]   Quantitation of SR 27417 in human plasma using electrospray liquid chromatography tandem mass spectrometry: A study of ion suppression [J].
Buhrman, DL ;
Price, PI ;
Rudewicz, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1996, 7 (11) :1099-1105
[8]   Immunoassay of estradiol: Unanticipated suppression by unconjugated estriol [J].
Cao, ZM ;
Swift, TA ;
West, CA ;
Rosano, TG ;
Rej, R .
CLINICAL CHEMISTRY, 2004, 50 (01) :160-165
[9]   Determination of estrogens and progestogens by mass spectrometric techniques (GC/MS, LC/MS and LC/MS/MS) [J].
Díaz-Cruz, MS ;
de Alda, MJL ;
López, R ;
Barceló, D .
JOURNAL OF MASS SPECTROMETRY, 2003, 38 (09) :917-923
[10]   Derivatization procedures for the detection of estrogenic chemicals by gas chromatography/mass spectrometry [J].
Ding, WH ;
Chiang, CC .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (01) :56-63