Simultaneous real-time visualization of the catheter tip and vascular anatomy for MR-guided PTA of iliac arteries in an animal model

被引:38
作者
Buecker, A
Adam, GB
Neuerburg, JM
Kinzel, S
Glowinski, A
Schaeffter, T
Rasche, V
van Vaals, JJ
Guenther, RW
机构
[1] Univ Technol Aachen, Clin Diagnost Radiol, D-52057 Aachen, Germany
[2] Univ Technol Aachen, Dept Expt Vet Med, Aachen, Germany
[3] Philips Res Labs, Hamburg, Germany
[4] Philips Med Syst, Best, Netherlands
关键词
MR-guided interventions; angioplasty; MR; real-time imaging;
D O I
10.1002/jmri.10148
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the feasibility of simultaneous MR real-time active tip tracking and near real-time depiction of the vascular anatomy for percutaneous angioplasty of iliac arteries under MR guidance. Material and Methods: Nine surgically created stenoses of external iliac arteries in pigs were dilated with MR-compatible balloon catheters (Cordis, Roden, the Netherlands). These catheters were equipped with a microcoil for active tracking of the catheter tip with an in-plane update rate of 10 positions per second. The procedures were performed on an interventional 1.5 T Gyroscan ACS-NT scanner (Philips, Best, The Netherlands). Real time calculation of images acquired by radical k-space filling was performed on a specially designed backprojector exploiting the sliding window reconstruction technique (Philips Research Laboratoires, Hamburg, Germany). The image update rate was 20 frames per second using a radial gradient echo technique (TR = 12 msec, TE = 3.3 msec, 300 radicals). MR angiography and X-ray digital subtraction angiography on the X-ray system positioned in-line next to the interventional MR system served as control for the angioplasty results. Results: Real-time guidance and positioning of the balloon catheters was possible. The actual position of the catheter tip was indicated in the MR images without any time delay for the reconstruction of the anatomical MR images, which were updated with a rate of 20 frames per second. this yielded a combination of a roadmap and fluoroscopy image, in which the catheter position and the anatomical background image both were continuously updated in real time. Six out of nine stenoses were successfully dilated. The effects of the angioplasty could be visualized by the real-time MR technique, as was proven by X-ray digital subtraction angiography. Conclusion: Active tip tracking simultaneous with MRI of the vascular anatomy - both in real time - is possible with the applied technique, enabling MR-guided percutaneous dilation (PTA) of iliac arteries.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 29 条
[1]  
Ackerman JL., 1986, Proceedings of the 5th Annual Meeting of ISMRM, P1131
[2]   Visualization of dedicated catheters using fast scanning techniques with potential for MR-guided vascular interventions [J].
Bakker, CJ ;
Hoogeveen, RM ;
Weber, J ;
vanVaals, JJ ;
Viergever, MA ;
Mali, WP .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :816-820
[3]   MR-guided balloon angioplasty: In vitro demonstration of the potential of MRI for guiding, monitoring, and evaluating endovascular interventions [J].
Bakker, CJ ;
Smits, HF ;
Bos, C ;
van der Weide, R ;
Zuiderveld, KJ ;
van Vaals, JJ ;
Hurtak, WF ;
Viergever, MA ;
Mall, WP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :245-250
[4]   Real-time MR guidance for inferior vena cava filter placement in an animal model [J].
Bücker, A ;
Neuerburg, JM ;
Adam, GB ;
Glowinski, A ;
Schaeffter, T ;
Rasche, V ;
van Vaals, JJ ;
Günther, RW .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (06) :753-756
[5]  
Buecker A, 2000, J MAGN RESON IMAGING, V12, P616, DOI 10.1002/1522-2586(200010)12:4<616::AID-JMRI15>3.0.CO
[6]  
2-F
[7]   REAL-TIME POSITION MONITORING OF INVASIVE DEVICES USING MAGNETIC-RESONANCE [J].
DUMOULIN, CL ;
SOUZA, SP ;
DARROW, RD .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :411-415
[8]   MR FLUOROSCOPY - INITIAL CLINICAL-STUDIES [J].
FARZANEH, F ;
RIEDERER, SJ ;
LEE, JN ;
TASCIYAN, T ;
WRIGHT, RC ;
SPRITZER, CE .
RADIOLOGY, 1989, 171 (02) :545-549
[9]   MR-guided transjugular portosystemic shunt placement in a swine model [J].
Kee, ST ;
Rhee, JS ;
Butts, K ;
Daniel, B ;
Pauly, J ;
Kerr, A ;
O'Sullivan, GJ ;
Sze, DY ;
Razavi, MK ;
Semba, CP ;
Herfkens, RJ ;
Dake, MD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (05) :529-535
[10]  
Konings MK, 2000, J MAGN RESON IMAGING, V12, P79, DOI 10.1002/1522-2586(200007)12:1<79::AID-JMRI9>3.3.CO