The Wagner-Nelson method can generate an accurate gastric emptying flow curve from 13CO2 data obtained by a 13C-labeled substrate breath test

被引:50
作者
Sanaka, M
Yamamoto, T
Ishii, T
Kuyama, Y
机构
[1] Teikyo Univ, Sch Med, Dept Internal Med, Itabashi Ku, Tokyo 1738605, Japan
[2] Tokyo Metropolitan Komagome Hosp, Dept Internal Med, Tokyo, Japan
关键词
breath testing; compartment model; gastric emptying; pharmacokinetics; Wagner-Nelson method;
D O I
10.1159/000077391
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: In pharmacokinetics, the Wagner-Nelson (W-N) method can accurately estimate the rate of drug absorption from its urinary elimination rate. A stable isotope (C-13) breath test attempts to estimate the rate of absorption of C-13, as an index of gastric emptying rate, from the rate of pulmonary elimination of (CO2)-C-13. The time-gastric emptying curve determined by the breath test is quite different from that determined by scintigraphy or ultrasonography. In this report, we have shown that the W-N method can adjust the difference. Methods: The W-N equation to estimate gastric emptying from breath data is as follows: the fractional cumulative amount of gastric contents emptied by time t=A(breath)(t)/A(breath)(infinity) +(1/0.65).d[A(breath)(t)/A(breath)(infinity)]/dt, where A(breath)(t)=the cumulative recovery of (CO2)-C-13 in breath by time t and A(breath)(infinity)=the ultimate cumulative (CO2)-C-13 recovery. The emptying flow curve generated by ultrasonography was compared with that generated by the W-N method-adjusted breath test in 6 volunteers. Results: The emptying curves by the W-N method were almost identical to those by ultrasound. Conclusions: The W-N method can generate an accurate emptying flow curve from (CO2)-C-13 data, and it can adjust the difference between ultrasonography and the breath test. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 23 条
[1]   Evaluation of gastric emptying measured with the 13C-octanoic acid breath test in patients with functional dyspepsia comparison with ultrasonography [J].
Aoki, S ;
Haruma, K ;
Kusunoki, H ;
Hata, J ;
Hara, M ;
Yoshida, S ;
Tanaka, S ;
Chayama, K .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2002, 37 (06) :662-666
[2]   SULFAMETHIZOLE CAPSULE METHOD - A NEW METHOD FOR ASSESSING GASTRIC-EMPTYING OF SOLIDS [J].
ASADA, T ;
MURAKAMI, M ;
SAKO, Y ;
FUKUSHIMA, Y ;
YONEKURA, Y ;
KONISHI, J ;
KITA, T ;
MIYAKE, T ;
ASADA, T .
DIGESTIVE DISEASES AND SCIENCES, 1994, 39 (09) :2056-2061
[3]   INFLUENCE OF INCREASED METABOLIC-RATE ON [C-13]BICARBONATE WASHOUT KINETICS [J].
BARSTOW, TJ ;
COOPER, DM ;
SOBEL, EM ;
LANDAW, EM ;
EPSTEIN, S .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 259 (01) :R163-R171
[4]   THE [C-13]ACETATE BREATH TEST ACCURATELY REFLECTS GASTRIC-EMPTYING OF LIQUIDS IN BOTH LIQUID AND SEMISOLID TEST MEALS [J].
BRADEN, B ;
ADAMS, S ;
DUAN, LP ;
ORTH, KH ;
MAUL, FD ;
LEMBCKE, B ;
HOR, G ;
CASPARY, WF .
GASTROENTEROLOGY, 1995, 108 (04) :1048-1055
[5]  
Cappello G, 2000, AM J GASTROENTEROL, V95, P3097
[6]   [C-13]octanoic acid breath test for gastric emptying of solids: Accuracy, reproducibility, and comparison with scintigraphy [J].
Choi, MG ;
Camilleri, M ;
Burton, DD ;
Zinsmeister, AR ;
Forstrom, LA ;
Nair, KS .
GASTROENTEROLOGY, 1997, 112 (04) :1155-1162
[7]   Correlation between simultaneous scintigraphic and ultrasonographic measurement of gastric emptying in patients with type 1 diabetes mellitus [J].
Darwiche, G ;
Björgell, O ;
Thorsson, O ;
Almér, LO .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (05) :459-466
[8]   MEASUREMENT OF GASTRIC-EMPTYING RATE OF SOLIDS BY MEANS OF A CARBON-LABELED OCTANOIC-ACID BREATH TEST [J].
GHOOS, YF ;
MAES, BD ;
GEYPENS, BJ ;
MYS, G ;
HIELE, MI ;
RUTGEERTS, PJ ;
VANTRAPPEN, G .
GASTROENTEROLOGY, 1993, 104 (06) :1640-1647
[9]   [C-13] BICARBONATE KINETICS IN HUMANS - INTRAINDIVIDUAL VS INTERINDIVIDUAL VARIATIONS [J].
IRVING, CS ;
WONG, WW ;
SHULMAN, RJ ;
SMITH, EO ;
KLEIN, PD .
AMERICAN JOURNAL OF PHYSIOLOGY, 1983, 245 (02) :R190-R202
[10]  
Kim DY, 2000, AM J GASTROENTEROL, V95, P3365