Numerical calculation of hemolysis levels in peripheral hemodialysis cannulas

被引:33
作者
De Wachter, D [1 ]
Verdonck, P [1 ]
机构
[1] Univ Ghent, Hydrol Lab, Inst Biomed Technol, B-9000 Ghent, Belgium
关键词
finite element; shear stress; red blood cell damage; power-law equation; laminar flow;
D O I
10.1046/j.1525-1594.2002.07079.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hemolysis in extracorporeal life support systems presents an underestimated problem. In this article, we investigate the hemolytic potential of peripheral hemodialysis cannulas numerically. An axisymmetrical finite element model of 3 cannula sizes was built (13G, 14G, and 16G) that was refined sufficiently in the vicinity of the cannula tip to compute accurately scalar shear stresses. Scalar shear stresses were utilized in Giersiepen's equation to calculate the red blood cell damage (RBD) along streamlines. The streamlines were chosen such that they bound a percentage of the blood flow through the cannula. By integration of the RBD results, the total damage of the cannula was determined and expressed in modified index of hemolysis for comparison with published results. Calculated RBD was overestimated by Giersiepen's equation. The ranking of the cannulas according to their hemolytic potential was preserved. This indicates that power-law equations may be suited for hemolysis prediction of laminar flow devices.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 33 条
[1]  
[Anonymous], 1997, Am J Kidney Dis, V30, pS15
[2]   Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics [J].
Apel, J ;
Paul, R ;
Klaus, S ;
Siess, T ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :341-347
[3]   19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses) [J].
Barbaro, V ;
Grigioni, M ;
Daniele, C ;
D'Avenio, G ;
Boccanera, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (11) :629-636
[4]  
BERNSTEIN EF, 1967, SURGERY, V61, P432
[5]   HEMOLYTIC EFFECTS OF ENERGY DISSIPATION IN FLOWING BLOOD [J].
BLUESTEI.M ;
MOCKROS, LF .
MEDICAL & BIOLOGICAL ENGINEERING, 1969, 7 (01) :1-&
[6]  
DEWACHTER D, 1999, P INT C NEPHR ISN, P322
[7]   Red cell injury assessed in a numeric model of a peripheral dialysis needle [J].
DeWachter, DS ;
Verdonck, PR ;
Verhoeven, RF ;
Hombrouckx, RO .
ASAIO JOURNAL, 1996, 42 (05) :M524-M529
[8]   Blood trauma in plastic haemodialysis cannulae [J].
DeWachter, DS ;
Verdonck, PR ;
DeVos, JY ;
Hombrouckx, RO .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (07) :366-370
[9]  
DHAENE M, 1989, CLIN NEPHROL, V31, P327
[10]   HEMODIALYSIS INTRAVASCULAR HEMOLYSIS AND KINKED BLOOD LINES [J].
GAULT, MH ;
DUFFETT, S ;
PURCHASE, L ;
MURPHY, J .
NEPHRON, 1992, 62 (03) :267-271