Motion artifact in T2-weighted fast spin-echo images of the liver: Effect on image contrast and reduction of artifact using respiratory triggering in normal volunteers

被引:19
作者
Choe, KA [1 ]
Smith, RC [1 ]
Wilkens, K [1 ]
Constable, RT [1 ]
机构
[1] YALE UNIV,SCH MED,DEPT DIAGNOST IMAGING,NEW HAVEN,CT 06510
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1997年 / 7卷 / 02期
关键词
fast spin echo; motion artifact; liver imaging; respiratory triggering;
D O I
10.1002/jmri.1880070207
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to evaluate the effect of respiratory motion on the image contrast of T2-weighted fast spin-echo (FSE) images of the liver as well as the reduction of motion artifact using respiratory triggering of the data acquisition. We imaged the livers of 10 healthy volunteers using a fast spin-echo T2-weighted sequence. Images were obtained both without and with patient triggering. Triggered images were acquired in a segmented fashion during multiple sequential breath-holds using an echo train of 8 or 16, both with and without now compensation (gradient moment nulling). Ratios of signal difference to noise (SD/N) of the liver and gallbladder as well as the liver and spleen were compared for all sequences. All of the triggered images showed statistically significant improvement of SD/N for the liver and gallbladder as well as for the liver and spleen when compared with the nontriggered images. Triggered images obtained with an echo train length of 8 and, with now compensation, showed the highest SD/N ratios. In one volunteer whose liver contained multiple small cysts, the triggered images showed improved visualization of individual cysts and identified a larger number of cysts. Respiratory motion causes a significant loss of contrast on T2-weighted fast spin-echo images of the liver. This can be reduced by using a segmented data acquisition triggered by the respiratory cycle obtained during sequential breath-holds.
引用
收藏
页码:298 / 302
页数:5
相关论文
共 36 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   THE EFFECT OF RESPIRATION ON THE CONTRAST AND SHARPNESS OF LIVER-LESIONS IN MRI [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :1-7
[3]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[4]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[5]   INFLUENCE OF PHYSIOLOGICAL MOTION ON THE APPEARANCE OF TISSUE IN MR IMAGES [J].
EHMAN, RL ;
MCNAMARA, MT ;
BRASCH, RC ;
FELMLEE, JP ;
GRAY, JE ;
HIGGINS, CB .
RADIOLOGY, 1986, 159 (03) :777-782
[6]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[7]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[8]   MR-IMAGING OF THE LIVER AT 1.5-T - VALUE OF SIGNAL AVERAGING IN SUPPRESSING MOTION ARTIFACTS [J].
GAZELLE, GS ;
SAINI, S ;
HAHN, PF ;
GOLDBERG, MA ;
HALPERN, EF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :335-337
[9]  
HAACKE E M, 1986, Magnetic Resonance Imaging, V4, P359, DOI 10.1016/0730-725X(86)91046-5
[10]   RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR [J].
HENNIG, J ;
NAUERTH, A ;
FRIEDBURG, H .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :823-833