Reproducibility of compartmental subchondral bone morphometry in the mouse tibiofemoral joint

被引:7
作者
Besler, Bryce A. [1 ]
Sondergaard, Rachel E. [1 ]
Mueller, Ralph [1 ]
Stok, Kathryn S. [1 ,2 ]
机构
[1] ETH, Inst Biomech, CH-8093 Zurich, Switzerland
[2] SCANCO Med AG, Bruttisellen, Switzerland
关键词
Microcomputed tomography; Quantitative; Image processing; Osteoarthritis; Knee; MICRO-COMPUTED TOMOGRAPHY; OSTEOARTHRITIS; CARTILAGE; MODEL; SEGMENTATION; IMAGES; KNEE; CT;
D O I
10.1016/j.bone.2015.09.014
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Aim: Evidence suggests that subchondral bone can be used as a predictor for the onset of osteoarthritis. As such, there is a need to accurately and reproducibly quantify subchondral bone in areas where osteoarthritis develops. In this paper, we present a novel technique for the segmentation of subchondral bone in the tibiofemoral joint and assess the reproducibility of this method with multiple measures and users. Methods: The right hind leg of seven C57BL/6 mice were excised and imaged in mu CT. The menisci and patella were manually segmented and the image data was Gaussian filtered and binarized. An in-house algorithm was used to generate cortical and epiphyseal volumes of interest and standard morphometric indices for bone were computed. The intraclass correlation coefficient (ICC), absolute precision error (PE(SD)), and precision error as a percentage of the coefficient of variation of the repeated measurements (PE(%CV)) were calculated for each index. Additionally, an inter-user study was performed using the same indices and statistics. Results: For repeated measures, ICC ranged from 0.869 (cortical bone volume fraction, femur) to 0.994 (degree of anisotropy, femur). Similarly, PE(%CV) ranged from 0.84% (cortical bone volume fraction, femur) to 5.11% (connectivity density, tibia). For repeated users, no effect was seen in the femur with a slight effect in the tibia. Conclusions: A novel method for the automatic segmentation of cortical and epiphyseal bone is presented and is shown to be reproducible in C57BL/6 mice. This tool will allow for high-throughput studies of osteoarthritis in animal models. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:649 / 653
页数:5
相关论文
共 21 条
[1]
Botter SM, 2006, BIORHEOLOGY, V43, P379
[2]
ADAMTS5-/- mice have less subchondral bone changes after induction of osteoarthritis through surgical instability: implications for a link between cartilage and subchondral bone changes [J].
Botter, S. M. ;
Glasson, S. S. ;
Hopkins, B. ;
Clockaerts, S. ;
Weinans, H. ;
van Leeuwen, J. P. T. M. ;
van Osch, G. J. V. M. .
OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (05) :636-645
[3]
Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[4]
Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysis [J].
Buie, Helen R. ;
Campbell, Graeme M. ;
Klinck, R. Joshua ;
MacNeil, Joshua A. ;
Boyd, Steven K. .
BONE, 2007, 41 (04) :505-515
[5]
Altered Trabecular Bone Structure and Delayed Cartilage Degeneration in the Knees of Collagen VI Null Mice [J].
Christensen, Susan E. ;
Coles, Jeffrey M. ;
Zelenski, Nicole A. ;
Furman, Bridgette D. ;
Leddy, Holly A. ;
Zauscher, Stefan ;
Bonaldo, Paolo ;
Guilak, Farshid .
PLOS ONE, 2012, 7 (03)
[6]
Cicuttini FM, 1997, J RHEUMATOL, V24, P1164
[7]
ACCURATE ASSESSMENT OF PRECISION ERRORS - HOW TO MEASURE THE REPRODUCIBILITY OF BONE DENSITOMETRY TECHNIQUES [J].
GLUER, CC ;
BLAKE, G ;
LU, Y ;
BLUNT, BA ;
JERGAS, M ;
GENANT, HK .
OSTEOPOROSIS INTERNATIONAL, 1995, 5 (04) :262-270
[8]
Cartilage and bone changes during development of post-traumatic osteoarthritis in selected LGXSM recombinant inbred mice [J].
Hashimoto, S. ;
Rai, M. F. ;
Janiszak, K. L. ;
Cheverud, J. M. ;
Sandell, L. J. .
OSTEOARTHRITIS AND CARTILAGE, 2012, 20 (06) :562-571
[9]
A new method for the model-independent assessment of thickness in three-dimensional images [J].
Hildebrand, T ;
Ruegsegger, P .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 :67-75
[10]
Micro-computed tomography-based highly automated 3D segmentation of the rat spine for quantitative analysis of metastatic disease Technical note [J].
Hojjat, Seyed-Parsa ;
Hardisty, Michael R. ;
Whyne, Cari M. .
JOURNAL OF NEUROSURGERY-SPINE, 2010, 13 (03) :367-370