Carbon nanotube based microfocus field emission x-ray source for microcomputed tomography

被引:143
作者
Liu, Zejian [1 ]
Yang, Guang
Lee, Yueh Z.
Bordelon, David
Lu, Jianping
Zhou, Otto
机构
[1] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Sch Med, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Curriculum Appl & Mat Sci, Chapel Hill, NC 27599 USA
关键词
D O I
10.1063/1.2345829
中图分类号
O59 [应用物理学];
学科分类号
摘要
Microcomputed tomography is now widely used for in vivo small animal imaging for cancer studies. Achieving high imaging quality of live objects requires the x-ray source to have both high spatial and temporal resolutions. Preliminary studies have shown that carbon nanotube (CNT) based field emission x-ray source has significant intrinsic advantages over the conventional thermionic x-ray tube including better temporal resolution and programmability. Here we report the design and characterization of a CNT based field emission x-ray source that also affords a high spatial resolution. The device uses modified asymmetric Einzel lenses for electron focusing and an elliptical shaped CNT cathode patterned by photolithography. Stable and small isotropic x-ray focal spot sizes were obtained. (c) 2006 American Institute of Physics.
引用
收藏
页数:3
相关论文
共 18 条
[1]   Micro-CT with respiratory and cardiac gating [J].
Badea, C ;
Hedlund, LW ;
Johnson, GA .
MEDICAL PHYSICS, 2004, 31 (12) :3324-3329
[2]   The use of microcomputed tomography to study microvasculature in small rodents [J].
Bentley, MD ;
Ortiz, MC ;
Ritman, EL ;
Romero, JC .
AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2002, 282 (05) :R1267-R1279
[3]  
Cavanaugh Dawn, 2004, Mol Imaging, V3, P55, DOI 10.1162/153535004773861723
[4]   Dynamic radiography using a carbon-nanotube-based field-emission x-ray source [J].
Cheng, Y ;
Zhang, J ;
Lee, YZ ;
Gao, B ;
Dike, S ;
Lin, W ;
Lu, JP ;
Zhou, O .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :3264-3267
[5]   High-resolution X-ray microtomography for the detection of lung tumors in living mice [J].
De Clerck, NM ;
Meurrens, K ;
Weiler, H ;
Van Dyck, D ;
Vanhoutte, G ;
Terpstra, P ;
Postnov, AA .
NEOPLASIA, 2004, 6 (04) :374-379
[6]  
*EUR COMM, 1999, 125435 EN
[7]   MICROFOCUS X-RAY SOURCES FOR 3D MICROTOMOGRAPHY [J].
FLYNN, MJ ;
HAMES, SM ;
REIMANN, DA ;
WILDERMAN, SJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :312-315
[8]  
Gao B, 2001, ADV MATER, V13, P1770, DOI 10.1002/1521-4095(200112)13:23<1770::AID-ADMA1770>3.3.CO
[9]  
2-7
[10]   Development of a carbon nanotube based microfocus x-ray tube with single focusing electrode [J].
Liu, Zejian ;
Zhang, Jian ;
Yang, Guang ;
Cheng, Yuan ;
Zhou, Otto ;
Lu, Jianping .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (05)