Micro-CT with respiratory and cardiac gating

被引:154
作者
Badea, C [1 ]
Hedlund, LW [1 ]
Johnson, GA [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Durham, NC 27710 USA
关键词
micro-CT; resolution; mouse; gating;
D O I
10.1118/1.1812604
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cardiopulmonary imaging in rodents using micro-computed tomography (CT) is a challenging task due to both cardiac and pulmonary motion and the limited fluence rate available from micro-focus x-ray tubes of most commercial systems. Successful imaging in the mouse requires recognition of both the spatial and temporal scales and their impact on the required fluence rate. Smaller voxels require an increase in the total number of photons (integrated fluence) used in the reconstructed image for constant signal-to-noise ratio. The faster heart rates require shorter exposures to minimize cardiac motion blur imposing even higher demands on the fluence rate. We describe a system with fixed tube/detector and with a rotating specimen. A large focal spot x-ray tube capable of producing high fluence rates with short exposure times was used. The geometry is optimized to match focal spot blur with detector pitch and the resolution limits imposed by the reproducibility of gating. Thus, it is possible to achieve isotropic spatial resolution of 100 Am with a fluence rate at the detector 250 times that of a conventional cone beam micro-CT system with rotating detector and microfocal x-ray tube. Motion is minimized for any single projection with 10 ms exposures that are synchronized to both cardiac and breathing motion. System performance was validated in vivo by studies of the cardiopulmonary structures in C57BL/6 mice, demonstrating the value of motion integration with a bright x-ray source. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:3324 / 3329
页数:6
相关论文
共 21 条
  • [1] American Society for Testing and Materials (ASTM), 1995, STAND TEST METH MEAS
  • [2] Cavanaugh Dawn, 2004, Mol Imaging, V3, P55, DOI 10.1162/153535004773861723
  • [3] CHEN BT, 2004, IN PRESS MAGN RESON
  • [4] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [5] Fundamental image quality limits for microcomputed tomography in small animals
    Ford, NL
    Thornton, MM
    Holdsworth, DW
    [J]. MEDICAL PHYSICS, 2003, 30 (11) : 2869 - 2877
  • [6] MR MICROSCOPY OF THE RAT LUNG USING PROJECTION RECONSTRUCTION
    GEWALT, SL
    GLOVER, GH
    HEDLUND, LW
    COFER, GP
    MACFALL, JR
    JOHNSON, GA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) : 99 - 106
  • [7] Glover G H, 1988, Magn Reson Annu, P299
  • [8] Hedlund Laurence W, 2002, ILAR J, V43, P159
  • [9] MR-compatible ventilator for small animals: computer-controlled ventilation for proton and noble gas imaging
    Hedlund, LW
    Cofer, GP
    Owen, SJ
    Johnson, GA
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 753 - 759
  • [10] Micro-CT in small animal and specimen imaging
    Holdsworth, David W.
    Thornton, Michael M.
    [J]. TRENDS IN BIOTECHNOLOGY, 2002, 20 (08) : S34 - S39