Contribution to the certification of B, Cd, Cu, Mg and Pb in a synthetic water sample, by use of isotope-dilution ICP-MS, for Comparison 12 of the International Measurement Evaluation Programme

被引:13
作者
Diemer, J [1 ]
Quétel, CR [1 ]
Taylor, PDP [1 ]
机构
[1] European Commiss, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
关键词
IDMS; ICP-IDMS; IMEP; certification; uncertainty budget;
D O I
10.1007/s00216-002-1333-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Systeme International d'Unites). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low mug kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high mumol kg(-1) level), SI-traceable reference values with relative expanded uncertainties (k=2) of less than 2% were obtained.
引用
收藏
页码:220 / 225
页数:6
相关论文
共 20 条
[1]  
[Anonymous], 1988, INORGANIC MASS SPECT
[2]  
[Anonymous], ISOTOPE DILUTION MAS
[3]   Atomic weights of the elements 1995 [J].
Coplen, TB .
PURE AND APPLIED CHEMISTRY, 1996, 68 (12) :2339-2359
[4]  
De Bievre P., 1993, ANAL PROC, V30, P328, DOI [10.1039/AP9933000328, DOI 10.1039/AP9933000328]
[5]   Determination of trace amounts of boron in rainwater by ICP-IDMS and NTI-IDMS and the dependence on meteorological and anthropogenic influences [J].
Demuth, N ;
Heumann, KG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1449-1453
[6]   Comparison of the performance of different ICP-MS instruments on the measurement of Cu in a water sample by ICP-IDMS [J].
Diemer, J ;
Quétel, CR ;
Taylor, PDP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (09) :1137-1142
[7]  
*EUR, 1995, QUANT UNC AN MEAS
[8]  
*GUM WORKSH, METR GMBH
[9]   ISOTOPE-DILUTION MASS-SPECTROMETRY (IDMS) OF THE ELEMENTS [J].
HEUMANN, KG .
MASS SPECTROMETRY REVIEWS, 1992, 11 (01) :41-67
[10]  
*INT ORG STAND, 1995, GUID EXPRE UNC MEAS