Variable selection by modified IPW (iterative predictor weighting)-PLS (partial least squares) in continuous wavelet regression models

被引:52
作者
Chen, D [1 ]
Hu, XG [1 ]
Shao, XG [1 ]
Su, QD [1 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
关键词
D O I
10.1039/b400410h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Variable selection is often used to produce more robust and parsimonious regression models. But when they are applied directly to the raw near-infrared spectra, it is not easy to select appropriate variables because background and noise will often overshadow or overlap the absorption bands of analyte. In this work, a new hybrid algorithm based on the selection of the most informative variables in the continuous wavelet transform (CWT) domain is described. The strategy is a combination of CWT and a procedure of modified iterative predictor weighting-partial least square (mIPW-PLS). After elimination of the background and noise in NIR spectra by CWT, the mIPW-PLS approach is used to select the most informative CWT coefficients. With the selected CWT coefficients, a PLS model is built finally for prediction. It is indicated that the extraction of most important variables in the CWT domain can effectively avoid the interference of background and noise, and result in a high quality of regression model with a very small number of variables and fewer PLS components.
引用
收藏
页码:664 / 669
页数:6
相关论文
共 35 条
[1]   Variable selection in wavelet regression models [J].
Alsberg, BK ;
Woodward, AM ;
Winson, MK ;
Rowland, JJ ;
Kell, DB .
ANALYTICA CHIMICA ACTA, 1998, 368 (1-2) :29-44
[2]  
Bakshi BR, 1999, J CHEMOMETR, V13, P415, DOI 10.1002/(SICI)1099-128X(199905/08)13:3/4<415::AID-CEM544>3.0.CO
[3]  
2-8
[4]   The continuous wavelet transform, an analysis tool for NMR spectroscopy [J].
Barache, D ;
Antoine, JP ;
Dereppe, JM .
JOURNAL OF MAGNETIC RESONANCE, 1997, 128 (01) :1-11
[5]   Analysis of aqueous solutions by near-infrared spectrometry (NIRS) .4. One- and two-component systems of organic compounds in water [J].
Berentsen, S ;
Stolz, T ;
Molt, K .
JOURNAL OF MOLECULAR STRUCTURE, 1997, 410 :581-585
[6]   WAVELENGTH SELECTION IN MULTICOMPONENT NEAR-INFRARED CALIBRATION [J].
BROWN, PJ .
JOURNAL OF CHEMOMETRICS, 1992, 6 (03) :151-161
[7]   Elimination of uninformative variables for multivariate calibration [J].
Centner, V ;
Massart, DL ;
deNoord, OE ;
deJong, S ;
Vandeginste, BM ;
Sterna, C .
ANALYTICAL CHEMISTRY, 1996, 68 (21) :3851-3858
[8]  
Chaupart N, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P307
[9]   Elimination of interference information by a new hybrid algorithm for quantitative calibration of near infrared spectra [J].
Chen, D ;
Wang, F ;
Shao, XG ;
Su, QD .
ANALYST, 2003, 128 (09) :1200-1203
[10]   A solution to the wavelet transform optimization problem in multicomponent analysis [J].
Coelho, CJ ;
Galvao, RKH ;
Araujo, MCU ;
Pimentel, MF ;
da Silva, EC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2003, 66 (02) :205-217