Silver-selective membrane electrodes using 2-mercaptobenzimidazole and 2-mercaptobenzothiazole carriers

被引:12
作者
Amini, MK [1 ]
Rafi, A [1 ]
Mohammadpoor-Baltork, I [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 81744, Iran
关键词
silver-selective electrode; sensors; coated-graphite electrode; potentiometric sensors; 2-mercaptobenzimidazole; 2-mercaptobenzothiazole; ion-selective electrode;
D O I
10.1081/AL-120013584
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Silver. ion-selective electrodes based on 2-mercaptobenzimidazole (MBI) and 2-mercaptobenzothiazole (MBT) carriers have been developed. The poly(vinyl chloride) (PVC)-based membranes containing MBI or MBT, plasticizer and sodium tetraphenylborate, as anion excluder and membrane modifier, were directly coated on the surface of graphite electrodes. The electrodes exhibited near-Nernstian slopes of 60.2 and 57.8 mV per decade of Ag+ concentration for MBI and MBT, respectively. Calibration plots were linear over a wide concentration range of 1 x 10(-6)-1 x 10(-2) M Ag+. The electrodes have shown detection limits of 6.3 x 10(-7) and 4 x 10(-7) M for MBI- and MBT-based electrodes, respectively, and revealed good selectivities over a number of alkali, alkaline earth, transition and heavy metal ions. The electrodes have response times between 10-20 s and can be used for at least two months without a considerable divergence in their potential responses Application of the electrodes for potentiometric titrations and determination of Ag+ ion concentration in photographic waste solutions are reported.
引用
收藏
页码:1795 / 1809
页数:15
相关论文
共 41 条
  • [21] COPPER(II)-SELECTIVE MEMBRANE ELECTRODES BASED ON ORTHO-XYLYLENE BIS(DITHIOCARBAMATES) AS NEUTRAL CARRIERS
    KAMATA, S
    MURATA, H
    KUBO, Y
    BHALE, A
    [J]. ANALYST, 1989, 114 (09) : 1029 - 1031
  • [22] Ion-selective electrode for the determination of trazodone in tablets
    Khalil, S
    [J]. ANALYST, 1999, 124 (02) : 139 - 142
  • [23] Silver ion-selective electrodes using π-coordinate calix[4]arene derivatives as soft neutral carriers
    Kimura, K
    Yajima, S
    Tatsumi, K
    Yokoyama, M
    Oue, M
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (21) : 5290 - 5294
  • [24] Polymeric membrane silver-ion selective electrodes based on bis(dialkyldithiophosphates)
    Liu, D
    Liu, JH
    Tian, DY
    Hong, WL
    Zhou, XM
    Yu, JC
    [J]. ANALYTICA CHIMICA ACTA, 2000, 416 (02) : 139 - 144
  • [25] Liquid membrane transport and silver selective electrode based on novel bis(3-pyridinecarboxylate) calix[4]arene as ionophore
    Liu, Y
    Zhao, BT
    Chen, LX
    He, XW
    [J]. MICROCHEMICAL JOURNAL, 2000, 65 (01) : 75 - 79
  • [26] Silver(I) ion selective PVC membrane based on bis-pyridine tetramide macrocycle
    Mahajan, RK
    Parkash, O
    [J]. TALANTA, 2000, 52 (04) : 691 - 693
  • [27] Mashhadizadeh MH, 1999, ANAL CHIM ACTA, V381, P111
  • [28] Mercury selective membrane electrodes using 2-mercaptobenzimidazole, 2-mercaptobenzothiazole, and hexathiacyclooctadecane carriers
    Mazloum-Ardakani, M
    Amini, MK
    Mohammadpoor-Baltork, I
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 80 - 85
  • [29] Coated-wire ion-selective electrodes for levobetaxolol
    Missel, PJ
    [J]. LANGMUIR, 1999, 15 (21) : 7122 - 7124
  • [30] NEUTRAL CARRIER-TYPE SILVER ION-SELECTIVE ELECTRODE BASED ON LIPOPHILIC MONOTHIACROWN ETHER
    OUE, M
    KIMURA, K
    AKAMA, K
    TANAKA, M
    SHONO, T
    [J]. CHEMISTRY LETTERS, 1988, (03) : 409 - 410