A novel analytical immunosensor array, based on a microtiter plate coupled to a multichannel electrochemical detection (MED) system using the intermittent pulse amperometry (IPA) technique, is proposed for the detection of aflatoxin B-1 (AFB(1)). In the present work, the electrochemical behaviour and electroanalytical performance of the thick-film carbon sensors (also designated as screen-printed electrodes) incorporated in the multichannel electrochemical plate were first evaluated. Then the 96-well screen-printed microplate was modified in accord with a competitive indirect enzyme-linked immunoassay (ELISA) format for aflatoxin B-1 detection. The measurements were performed using both spectrophotometric and electrochemical procedures and the results of the calibration curves, detection limit (LOD), sensitivity and reproducibility of the respective assay systems were evaluated. The immunoassay was then applied for analysis of corn samples spiked with AFB(1) before and after the extraction treatment, in order to study the extraction efficiency and the matrix effect, respectively. These studies have shown that using this system, AFB(1) can be measured at a level of 30 pg/mL and with a working range between 0.05 and 2 ng/mL. Good recoveries (103 +/- 8%) were obtained, demonstrating the suitability of the proposed assay for accurate determination of the AFB(1) concentration in corn samples. The specificity of the assay was assessed by studying the cross-reactivity of PAb relative to AFB(1). The results indicated that the PAb could readily distinguish AFB(1) from other aflatoxins, with the exception for AFG(1). (c) 2006 Elsevier B.V. All fights reserved.
引用
收藏
页码:1434 / 1440
页数:7
相关论文
共 31 条
  • [1] Electrochemical immunosensor for determination of aflatoxin B1 in barley
    Ammida, NHS
    Micheli, L
    Palleschi, G
    [J]. ANALYTICA CHIMICA ACTA, 2004, 520 (1-2) : 159 - 164
  • [2] [Anonymous], 1993, IARC MON EV CARC RIS
  • [3] *AOAC INT, 2004, AOAC INT PERF TEST M
  • [4] AVIDIN-BIOTIN BASED ELECTROCHEMICAL IMMUNOASSAY FOR THYROTROPIN
    ATHEY, D
    BALL, M
    MCNEIL, CJ
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 1993, 30 : 570 - 577
  • [5] Determination of aflatoxin levels in some dairy and food products which consumed in Ankara, Turkey
    Aycicek, H
    Aksoy, A
    Saygi, S
    [J]. FOOD CONTROL, 2005, 16 (03) : 263 - 266
  • [6] CHU FS, 1987, J ASSOC OFF ANA CHEM, V70, P854
  • [7] Cole R. J., 1981, Handbook of Toxic Fungal Metabolites
  • [8] Disposable screen-printed electrodes for the immunochemical detection of polychlorinated biphenyls
    DelCarlo, M
    Lionti, I
    Taccini, M
    Cagnini, A
    Mascini, M
    [J]. ANALYTICA CHIMICA ACTA, 1997, 342 (2-3) : 189 - 197
  • [9] Isolation of aflatoxigenic strains of Aspergillus and detection of aflatoxin B1 from feeds in India
    Dutta, TK
    Das, P
    [J]. MYCOPATHOLOGIA, 2001, 151 (01) : 29 - 33
  • [10] EDWARDS R, 1997, PRINCIPLES PRACTICE, P325