Multi-syringe flow injection solid-phase extraction system for on-line simultaneous spectrophotometric determination of nitro-substituted phenol isomers

被引:36
作者
Manera, Matias [1 ]
Miro, Manuel [1 ]
Estela, Jose Manuel [1 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Fac Sci, E-07122 Palma de Mallorca, Spain
关键词
nitrophenol isomers; multi-syringe flow injection analysis; sorbent extraction; multivariate regression modelling;
D O I
10.1016/j.aca.2006.08.063
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a time-based multi-syringe flow injection (MSFI) approach is proposed for automated disk-based sorbent extraction of three nitro-substituted phenol isomers (2-, 3-, and 4-nitrophenol) followed by on-line simultaneous determination of individual species by diode-array spectrophotometry. The method involves the on-line enrichment of the targeted analytes from an acidic medium containing 0.1 mol L-1 HCl onto a co-polymeric sorbent material, and the concurrent removal of potentially interfering matrix components. The nitrophenol isomers are subsequently eluted with an alkaline solution (0.7 mol L-1 NaOH), whereupon the eluate is delivered to a diode-array spectrophotometer for recording of the spectral data in the UV-vis region. Deconvolution of strongly overlapped spectra was conducted with multivariate regression models based on multiple linear regression calibration. The analytical performance of the chemometric algorithm was characterized by relative prediction errors and recoveries. The MSFI manifold was coupled to a multiposition selection valve to set a rugged analyzer that ensures minimum operational maintenance via exploitation of membrane switching protocols. As compared with earlier methods for isolation/pre-concentration of nitro-substituted phenols based on liquid-liquid extraction, the proposed flow-through disk-based system should be regarded as an environmentally friendly approach because the use of harmful organic solvents is circumvented. Under the optimized chemical and physical variables, the 30 sigma(blank) detection limits for 2-, 3-, and 4-nitrophenol were 1.2, 3.2 and 0.3 mu mol L-1 for a sample loading volume of 1.5 mL, and the relative standard deviations were <= 5.0%. The flowing system, which is able to handle up to 135 samples automatically, was proven suitable for monitoring trace levels of the target isomers in mineral, tap, and seawater. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 36 条
[1]   Resolution of a multicomponent polycyclic aromatic hydrocarbon system in micellar media by linear variable angle fluorescence applying distinct chemometric techniques [J].
Amador-Hernández, J ;
Cladera, A ;
Estela, JM ;
López-de-Alba, PL ;
Cerdà, V .
ANALYST, 1998, 123 (11) :2235-2241
[2]  
[Anonymous], 1984, FED REG, P58
[3]  
Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
[4]  
2-9
[5]   MULTICOMPONENT ANALYSIS OF ENVIRONMENTAL MATRICES [J].
CERDA, V ;
ESTELA, JM ;
FORTEZA, R ;
CLADERA, A ;
GOMEZ, E ;
OMS, MT .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1993, 52 (1-4) :159-178
[6]   Multicomponent sequential injection analysis determination of nitro-phenols in waters by on-line liquid-liquid extraction and preconcentration [J].
Cladera, A ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2000, 421 (02) :155-166
[7]   Solid-phase extraction method for the determination of free and conjugated phenol compounds in human urine [J].
Crespín, MA ;
Gallego, M ;
Valcarcel, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02) :89-96
[8]   Simultaneous determination of fluorophores with overlapped spectra by sequential injection analysis coupled to variable angle scanning fluorescence spectrometry and multivariate linear regression algorithms [J].
de Armas, G ;
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2002, 471 (02) :173-186
[9]   A critical examination of the components of the Schlieren effect in flow analysis [J].
Dias, ACB ;
Borges, EP ;
Zagatto, EAG ;
Worsfold, PJ .
TALANTA, 2006, 68 (04) :1076-1082
[10]  
Dinc E., 2005, IL FARMACO, V60, P591