In this paper, a time-based multi-syringe flow injection (MSFI) approach is proposed for automated disk-based sorbent extraction of three nitro-substituted phenol isomers (2-, 3-, and 4-nitrophenol) followed by on-line simultaneous determination of individual species by diode-array spectrophotometry. The method involves the on-line enrichment of the targeted analytes from an acidic medium containing 0.1 mol L-1 HCl onto a co-polymeric sorbent material, and the concurrent removal of potentially interfering matrix components. The nitrophenol isomers are subsequently eluted with an alkaline solution (0.7 mol L-1 NaOH), whereupon the eluate is delivered to a diode-array spectrophotometer for recording of the spectral data in the UV-vis region. Deconvolution of strongly overlapped spectra was conducted with multivariate regression models based on multiple linear regression calibration. The analytical performance of the chemometric algorithm was characterized by relative prediction errors and recoveries. The MSFI manifold was coupled to a multiposition selection valve to set a rugged analyzer that ensures minimum operational maintenance via exploitation of membrane switching protocols. As compared with earlier methods for isolation/pre-concentration of nitro-substituted phenols based on liquid-liquid extraction, the proposed flow-through disk-based system should be regarded as an environmentally friendly approach because the use of harmful organic solvents is circumvented. Under the optimized chemical and physical variables, the 30 sigma(blank) detection limits for 2-, 3-, and 4-nitrophenol were 1.2, 3.2 and 0.3 mu mol L-1 for a sample loading volume of 1.5 mL, and the relative standard deviations were <= 5.0%. The flowing system, which is able to handle up to 135 samples automatically, was proven suitable for monitoring trace levels of the target isomers in mineral, tap, and seawater. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 36 条
[11]   Sequential-injection analysis (SIA): A useful tool for on-line sample-handling and pre-treatment [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (05) :416-425
[12]  
Fang Z., 1993, FLOW INJECTION SEPAR, P74
[13]   SPECTROPHOTOMETRIC DETERMINATION OF TOTAL PHENOLICS BY SOLVENT-EXTRACTION AND SORBENT EXTRACTION OPTOSENSING USING FLOW-INJECTION METHODOLOGY [J].
FRENZEL, W ;
KREKLER, S .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :437-446
[14]   Implementation of suitable flow injection/sequential injection-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry [J].
Hansen, EH ;
Wang, JH .
ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) :3-12
[15]   Sequential injection analysis [J].
Lenehan, CE ;
Barnett, NW ;
Lewis, SW .
ANALYST, 2002, 127 (08) :997-1020
[16]   Optimization of a derivatization-solid-phase microextraction method for the analysis of thirty phenolic pollutants in water samples [J].
Llompart, M ;
Lourido, M ;
Landín, P ;
García-Jares, C ;
Cela, R .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :137-148
[18]   Potentials of multisyringe flow injection analysis for chemiluminescence detection [J].
Miró, M ;
Estela, JM ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) :57-68
[19]   Flow-through sorptive preconcentration with direct optosensing at solid surfaces for trace-ion analysis [J].
Miró, M ;
Frenzel, W .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (01) :11-20
[20]   A novel flow-through disk-based solid-phase extraction diffuse reflectance optrode.: Application to preconcentration and determination of trace levels of nitrite [J].
Miró, M ;
Frenzel, W ;
Estela, JM ;
Cerdà, V .
ANALYST, 2001, 126 (10) :1740-1746