Sequential-injection analysis (SIA): A useful tool for on-line sample-handling and pre-treatment

被引:100
作者
Economou, A [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
dilution; enzymatic analysis; extraction; gas diffusion; immunological analysis; sequential-injection analysis;
D O I
10.1016/j.trac.2004.12.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, sequential-injection analysis (SIA) is reviewed as a tool for on-line sample manipulation and sample pre-treatment. Although SIA is an established technique for performing solution chemistry, its great potential lies in the scope it offers for the more complicated on-line sample-manipulation stages before the measurement step. This review will demonstrate the scope of SIA in complex sample-handling procedures with examples of online sample dilution, dialysis and gas diffusion, extraction (liquid/liquid, gas/liquid and solid-phase), enzymatic and immunological assays, and various other on-line operations. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:416 / 425
页数:10
相关论文
共 58 条
[1]   Fluorimetric determination of aluminium in water by sequential injection through column extraction [J].
Brach-Papa, C ;
Coulomb, B ;
Branger, C ;
Margaillan, A ;
Théraulaz, F ;
Van Loot, P ;
Boudenne, JL .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) :1652-1658
[2]   Renewable microcolumns for solid-phase nucleic acid separations and analysis from environmental samples [J].
Chandler, DP ;
Brockman, FJ ;
Holman, DA ;
Grate, JW ;
Bruckner-Lea, CJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (05) :314-321
[3]   Simultaneous determination of pH, chloride and nickel in electroplating baths using sequential injection analysis [J].
da Silva, JE ;
Pimentel, MF ;
da Silva, VL ;
Montenegro, MD ;
Araújo, AN .
ANALYTICA CHIMICA ACTA, 2004, 506 (02) :197-202
[4]   Development of solid-phase chemiluminescence immunoassays for digoxin comparing flow injection and sequential injection techniques [J].
Dreveny, D ;
Michalowski, J ;
Seidl, R ;
Gübitz, G .
ANALYST, 1998, 123 (11) :2271-2276
[5]   Flow-injection- and sequential-injection immunoassay for triiodothyronine using acridinium ester chemiluminescence detection [J].
Dreveny, D ;
Klammer, C ;
Michalowsky, J ;
Gübitz, G .
ANALYTICA CHIMICA ACTA, 1999, 398 (2-3) :183-190
[6]   Determination of primary explosive azides in environmental samples by sequential injection amperometry [J].
Echols, RT ;
James, RR ;
Aldstadt, JH .
ANALYST, 1997, 122 (04) :315-319
[7]   LabVIEW-based sequential-injection analysis system for the determination of trace metals by square-wave anodic and adsorptive stripping voltammetry on mercury-film electrodes [J].
Economou, A ;
Voulgaropoulos, A .
JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2003, 25 (06) :133-140
[8]   Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction (review) [J].
Fang, ZL ;
Fang, Q .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08) :978-983
[9]   Sequential injection analysis as a tool for in situ monitoring of Fe(II), Fe(III), NO3- and NO2- in natural and waste waters [J].
Galhardo, CX ;
Masini, JC .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :39-48
[10]   Novel colorimetric immunoassay for the detection of aflatoxin B1 [J].
Garden, SR ;
Strachan, NJC .
ANALYTICA CHIMICA ACTA, 2001, 444 (02) :187-191