Impact of final Stent dimensions on long-term results following sirolimus-eluting stent implantation - Serial intravascular ultrasound analysis from the SIRIUS trial

被引:342
作者
Sonoda, S
Morino, Y
Ako, J
Terashima, M
Hassan, AHM
Bonneau, HN
Leon, MB
Moses, JW
Yock, PG
Honda, Y
Kuntz, RE
Fitzgerald, PJ
机构
[1] Stanford Univ, Ctr Med, Ctr Res Cardiovasc Intervent, Stanford, CA 94305 USA
[2] Highlands Consulting Inc, San Jose, CA USA
[3] Lenox Hill Hosp, New York, NY 10021 USA
[4] Brigham & Womens Hosp, Boston, MA 02115 USA
关键词
D O I
10.1016/j.jacc.2004.01.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We assessed the predictive value of minimum stent area (MSA) for long-term patency of sirolimus-eluting stents (SES) implantation compared to bare metal stents (BMS). BACKGROUND Although MSA is a consistent predictor of in-stent restenosis, its predictive value in BMS is still limited because of biologic variability in the restenosis process. METHODS From the SIRolImUS (SIRIUS) trial, 122 cases (SES: 72; BMS: 50) with complete serial intravascular ultrasound (IVUS) (baseline and 8-month follow-up) were analyzed. Postprocedure MSA and follow-up minimum lumen area (MLA) were obtained. Based on previous physiologic studies, adequate stent patency at follow-up was defined as MLA >4 mm(2). RESULTS In both groups, a significant positive correlation was observed between baseline MSA and follow-up MLA (SES: p < 0.0001, BMS: p < 0.0001). However, SES showed higher correlation than BMS (0.8 vs. 0.65) with a higher regression coefficient (0.92 vs. 0.59). The sensitivity and specificity curves identified different optimal thresholds of MSA to predict adequate follow-up MLA: 5 mm(2) for SES and 6.5 mm(2) for BMS. The positive predictive values with these cutoff points were 90% and 56%, respectively. CONCLUSIONS In this SIRIUS IVUS substudy, SES reduced both biologic variability and restenosis, resulting in increased predictability of long-term stent patency with postprocedure MSA. In addition, SES had a considerably lower optimal MSA threshold compared to BMS. (C) 2004 by the American College of Cardiology Foundation.
引用
收藏
页码:1959 / 1963
页数:5
相关论文
共 22 条
  • [1] Long-term follow-up after percutaneous transluminal coronary angioplasty was not performed based on intravascular ultrasound findings - Importance of lumen dimensions
    Abizaid, AS
    Mintz, GS
    Mehran, R
    Abizaid, A
    Lansky, AJ
    Pichard, AD
    Satler, LF
    Wu, HS
    Pappas, C
    Kent, KM
    Leon, MB
    [J]. CIRCULATION, 1999, 100 (03) : 256 - 261
  • [2] Angiographic and clinical outcome following coronary stenting of small vessels - A comparison with coronary stenting of large vessels
    Akiyama, T
    Moussa, I
    Reimers, B
    Ferraro, M
    Kobayashi, Y
    Blengino, S
    Di Francesco, L
    Finci, L
    Di Mario, C
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) : 1610 - 1618
  • [3] Local drug delivery systems and prevention of restenosis
    Brieger, D
    Topol, E
    [J]. CARDIOVASCULAR RESEARCH, 1997, 35 (03) : 405 - 413
  • [4] Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography
    de Feyter, PJ
    Kay, P
    Disco, C
    Serruys, PW
    [J]. CIRCULATION, 1999, 100 (17) : 1777 - 1783
  • [5] SMALL STENT SIZE AND INTIMAL HYPERPLASIA CONTRIBUTE TO RESTENOSIS - A VOLUMETRIC INTRAVASCULAR ULTRASOUND ANALYSIS
    DUSSAILLANT, GR
    MINTZ, GS
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    WONG, SC
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (03) : 720 - 724
  • [6] DIFFERENCES IN RESTENOSIS PROPENSITY OF DEVICES FOR TRANSLUMINAL CORONARY INTERVENTION - A QUANTITATIVE ANGIOGRAPHIC COMPARISON OF BALLOON ANGIOPLASTY, DIRECTIONAL ATHERECTOMY, STENT IMPLANTATION AND EXCIMER-LASER ANGIOPLASTY
    FOLEY, DP
    MELKERT, R
    UMANS, VA
    DEJAEGERE, PP
    STRIKWERDA, S
    DEFEYTER, PJ
    SERRUYS, PW
    MOREL, MA
    VANSWIJNDREGT, EM
    [J]. EUROPEAN HEART JOURNAL, 1995, 16 (10) : 1331 - 1346
  • [7] Heldman AW, 2001, CIRCULATION, V103, P2289
  • [8] Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents
    Hoffmann, R
    Mintz, GS
    Kent, KM
    Satler, LF
    Pichard, AD
    Popma, JJ
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) : 951 - &
  • [9] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [10] Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents
    Hoffmann, R
    Mintz, GS
    Mehran, R
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Wu, HS
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) : 43 - 49