Comparison of an imaging heel quantitative ultrasound device (DTU-one) with densitometric and ultrasonic measurements

被引:16
作者
Diessel, E [1 ]
Fuerst, T [1 ]
Njeh, CF [1 ]
Hans, D [1 ]
Cheng, S [1 ]
Genant, HK [1 ]
机构
[1] Univ San Francisco, Osteoporosis & Arthrit Res Grp, San Francisco, CA 94117 USA
关键词
D O I
10.1259/bjr.73.865.10721316
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate a new imaging ultrasound scanner for the heel, the DTU-one (Osteometer MediTech, Denmark), by comparing quantitative ultrasound (QUS) results with bone mineral density (BMD) of the heel and femur from dual X-ray absorptiometry (DXA), and by comparing the DTU-one with another QUS device, the UBA 575+. The regions of interest in the DXA heel scan were matched with the regions evaluated by the two QUS devices. 134 healthy and 16 osteoporotic women aged 30-84 years old were enrolled in the study. In vivo short-term precision of the DTU-one for broadband ultrasound attenuation (BUA) and speed of sound (SOS) was 2.9% and 0.1%, respectively, and long-term precision was 3.8% and 0.2%, respectively. Highest correlations (r) between QUS and BMD measurements were achieved when comparing DTU-one results with BMD in matched regions of the DXA heel scan. Correlation coefficients (r) were 0.81 for BUA and SOS. Highest correlations with the UBA 575+ were 0.68 and 0.72, respectively. The comparison of BMD in different femoral sites with BUA and SOS (DTU-one) varied from 0.62 to 0.69 when including the entire study population. The correlation between BMD values within different sites of the femur tended to be higher (from r=0.81 to 0.93). When comparing BUA with BUA and SOS with SOS on the two QUS devices, the absolute QUS Values differed significantly. However, correlations were relatively high, with 0.76 for BUA and 0.82 for SOS. In conclusion, the results of the new quantitative ultrasound device, the DTU-one, are highly correlated (r=0.8) with results obtained using the UBA 575+ and with BMD in the heel. The precision of the DTU-one is comparable to other QUS devices for BUA and is high for SOS.
引用
收藏
页码:23 / 30
页数:8
相关论文
共 30 条
  • [21] Improved reproducibility of broadband ultrasound attenuation of the os calcis by using a specific region of interest
    Jorgensen, HL
    Hassager, C
    [J]. BONE, 1997, 21 (01) : 109 - 112
  • [22] Langton C M, 1984, Eng Med, V13, P89, DOI 10.1243/EMED_JOUR_1984_013_022_02
  • [23] Ultrasound parametric imaging of the calcaneus: In vivo results with a new device
    Laugier, P
    Fournier, B
    Berger, G
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1996, 58 (05) : 326 - 331
  • [24] The role of ultrasound in the assessment of osteoporosis: A review
    Njeh, CF
    Boivin, CM
    Langton, CM
    [J]. OSTEOPOROSIS INTERNATIONAL, 1997, 7 (01) : 7 - 22
  • [25] A precise method for the assessment of tibial ultrasound velocity
    Orgee, JM
    Foster, H
    McCloskey, EV
    Khan, S
    Coombes, G
    Kanis, JA
    [J]. OSTEOPOROSIS INTERNATIONAL, 1996, 6 (01) : 1 - 7
  • [26] PREDICTION OF HIP FRACTURE IN ELDERLY WOMEN - A PROSPECTIVE-STUDY
    PORTER, RW
    MILLER, CG
    GRAINGER, D
    PALMER, SB
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1990, 301 (6753): : 638 - 641
  • [27] COMPARISON OF BROAD-BAND ULTRASOUND ATTENUATION TO SINGLE X-RAY ABSORPTIOMETRY MEASUREMENTS AT THE CALCANEUS IN POSTMENOPAUSAL WOMEN
    SALAMONE, LM
    KRALL, EA
    HARRIS, S
    DAWSONHUGHES, B
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1994, 54 (02) : 87 - 90
  • [28] VELOCITY OF ULTRASOUND AND ITS ASSOCIATION WITH FRACTURE HISTORY IN A RURAL-POPULATION
    STEGMAN, MR
    HEANEY, RP
    RECKER, RR
    TRAVERSGUSTAFSON, D
    LEIST, J
    [J]. AMERICAN JOURNAL OF EPIDEMIOLOGY, 1994, 139 (10) : 1027 - 1034
  • [29] Prediction of fractures in perimenopausal women: A comparison of dual energy x ray absorptiometry and broadband ultrasound attenuation
    Stewart, A
    Torgerson, DJ
    Reid, DM
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1996, 55 (02) : 140 - 142
  • [30] THE RELATIONSHIP BETWEEN ULTRASOUND AND DENSITOMETRIC MEASUREMENTS OF BONE MASS AT THE CALCANEUS IN WOMEN
    WAUD, CE
    LEW, R
    BARAN, DT
    [J]. CALCIFIED TISSUE INTERNATIONAL, 1992, 51 (06) : 415 - 418