Uncertainties in alanine dosimetry in the therapeutic dose range

被引:49
作者
Nagy, V [1 ]
Sholom, SV
Chumak, VV
Desrosiers, MF
机构
[1] NIST, Ionizing Radiat Div, Gaithersburg, MD 20899 USA
[2] Acad Med Sci, Sci Ctr Radiat Med, UA-252050 Kiev, Ukraine
关键词
electron paramagnetic resonance; electron spin resonance; alanine; transfer dosimetry; Monte Carlo simulation; orthogonal regression;
D O I
10.1016/S0969-8043(01)00271-8
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A method for evaluating the overall uncertainty of alanine EPR transfer dosimetry in the therapeutic dose range is described. The method uses experimental data on EPR signal reproducibility from replicate dosimeters irradiated to low doses (1-5Gy), estimates of Type B uncertainties, and Monte Carlo simulations of heteroscedastic orthogonal linear regression. A Bruker ECS106 spectrometer and Bruker alanine dosimeters have been used for this evaluation. The results demonstrate that alanine dosimetry can be used for transfer dosimetry in that range with the overall uncertainty 1.5-4% (1sigma) depending on the dose. the number of replicate dosimeters. and the duration of the calibration session (the session should not exceed one working day), Published by Elsevier Science Ltd.
引用
收藏
页码:917 / 929
页数:13
相关论文
共 44 条
[31]   Alanine dosimetry of proton therapy beams [J].
Onori, S ;
dErrico, F ;
DeAngelis, C ;
Egger, E ;
Fattibene, P ;
Janovsky, I .
MEDICAL PHYSICS, 1997, 24 (03) :447-453
[32]   Proton response of alanine based pellets and films [J].
Onori, S ;
DErrico, F ;
DeAngelis, C ;
Egger, E ;
Fattibene, P ;
Janovsky, I .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1201-1204
[33]   OPTIMAL EXPERIMENTAL DESIGNS FOR ESTIMATING INDEPENDENT VARIABLE IN REGRESSION [J].
OTT, RL ;
MYERS, RH .
TECHNOMETRICS, 1968, 10 (04) :811-&
[34]   On lines and planes of closest fit to systems of points in space. [J].
Pearson, Karl .
PHILOSOPHICAL MAGAZINE, 1901, 2 (7-12) :559-572
[35]   Improvement of sensitivity in the Alanine/ESR dosimetry [J].
Rakvin, B .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (5-6) :525-528
[36]   UNIVARIATE REGRESSION-MODELS WITH ERRORS IN BOTH AXES [J].
RIU, J ;
RIUS, FX .
JOURNAL OF CHEMOMETRICS, 1995, 9 (05) :343-362
[37]   Numerical signal treatment for optimized alanine/ESR dosimetry in the therapy-level dose range [J].
Ruckerbauer, F ;
Sprunck, M ;
Regulla, DF .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1263-1268
[38]   Progress towards an alanine/ESR therapy level reference dosimetry service at NPL [J].
Sharpe, PHG ;
Rajendran, K ;
Sephton, JP .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1171-1175
[39]   Advancements in accuracy of the alanine dosimetry system. Part 1. The effects of environmental humidity [J].
Sleptchonok, OF ;
Nagy, V ;
Desrosiers, MF .
RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (02) :115-133
[40]  
Taylor B. N., 1994, 1297 NIST