Review of the use of biosensors as analytical tools in the food and drink industries

被引:354
作者
Mello, LD [1 ]
Kubota, LT [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
biosensors; food analysis; enzyme electrodes; immunosensors;
D O I
10.1016/S0308-8146(02)00104-8
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The food and drink industries need rapid and affordable methods to assure the quality of products and process control, where the use of analytical methods such as high performance liquid chromatography (HPLC) or specific enzymatic methods may be costly or laborious. Application of the biosensor technique in the field of food processing and quality control is promising. Biosensors offer advantages as alternatives to conventional methods due to their inherent specificity, simplicity and quick response. This article presents a review about the potential application of biosensor technology in drink and food industries, its current situation and potential. Some biosensors recently described in the literature are also listed. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:237 / 256
页数:20
相关论文
共 196 条
[71]  
HAMID IA, 1998, ELECTROANAL, V10, P758
[72]   Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor [J].
Harteveld, JLN ;
Nieuwenhuizen, MS ;
Wils, ERJ .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (07) :661-667
[73]   Enzymatic assay of histamine by amperometric detection of H2O2 with a peroxidase-based sensor [J].
Hibi, T ;
Senda, M .
BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2000, 64 (09) :1963-1966
[74]   Surface plasmon resonance sensors: review [J].
Homola, J ;
Yee, SS ;
Gauglitz, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) :3-15
[75]   Characterization of the interactions between immobilized parathion and the corresponding recombinant scFv antibody using a piezoelectric biosensor [J].
Horácek, J ;
Garrett, SD ;
Skládal, P ;
Morgan, MRA .
FOOD AND AGRICULTURAL IMMUNOLOGY, 1998, 10 (04) :363-374
[76]   Amperometric sensor for fish freshness based on immobilized multi-enzyme modified electrode [J].
Hu, SS ;
Liu, CC .
ELECTROANALYSIS, 1997, 9 (16) :1229-1233
[77]  
Imabayashi S, 2001, ELECTROANAL, V13, P408, DOI 10.1002/1521-4109(200104)13:5<408::AID-ELAN408>3.0.CO
[78]  
2-2
[79]  
Indyk HE, 2000, J AOAC INT, V83, P1141
[80]   Comparative investigation of electrochemical cholinesterase biosensors for pesticide determination [J].
Ivanov, AN ;
Evtugyn, GA ;
Gyurcsányi, RE ;
Tóth, K ;
Budnikov, HC .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :55-65