Methods for Clinical Evaluation of Noise Reduction Techniques in Abdominopelvic CT

被引:134
作者
Ehman, Eric C. [1 ]
Yu, Lifeng [1 ]
Manduca, Armando [1 ]
Hara, Amy K. [3 ]
Shiung, Maria M. [1 ]
Jondal, Dayna [1 ]
Lake, David S. [2 ]
Paden, Robert G. [3 ]
Blezek, Daniel J. [2 ]
Bruesewitz, Michael R. [1 ]
McCollough, Cynthia H. [1 ]
Hough, David M. [1 ]
Fletcher, Joel G. [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biomed Engn, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Radiol, Scottsdale, AZ USA
关键词
STATISTICAL ITERATIVE RECONSTRUCTION; FILTERED BACK-PROJECTION; RADIATION-DOSE REDUCTION; RAY COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ABDOMINAL CT; TRANSMISSION TOMOGRAPHY; CROHNS-DISEASE; HELICAL CT; ENTEROGRAPHY;
D O I
10.1148/rg.344135128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Most noise reduction methods involve nonlinear processes, and objective evaluation of image quality can be challenging, since image noise cannot be fully characterized on the sole basis of the noise level at computed tomography (CT). Noise spatial correlation (or noise texture) is closely related to the detection and characterization of low-contrast objects and may be quantified by analyzing the noise power spectrum. High-contrast spatial resolution can be measured using the modulation transfer function and section sensitivity profile and is generally unaffected by noise reduction. Detectability of low-contrast lesions can be evaluated subjectively at varying dose levels using phantoms containing low-contrast objects. Clinical applications with inherent high-contrast abnormalities (eg, CT for renal calculi, CT enterography) permit larger dose reductions with denoising techniques. In low-contrast tasks such as detection of metastases in solid organs, dose reduction is substantially more limited by loss of lesion conspicuity due to loss of low-contrast spatial resolution and coarsening of noise texture. Existing noise reduction strategies for dose reduction have a substantial impact on lowering the radiation dose at CT. To preserve the diagnostic benefit of CT examination, thoughtful utilization of these strategies must be based on the inherent lesion-to-background contrast and the anatomy of interest. The authors provide an overview of existing noise reduction strategies for low-dose abdominopelvic CT, including analytic reconstruction, image and projection space denoising, and iterative reconstruction; review qualitative and quantitative tools for evaluating these strategies; and discuss the strengths and limitations of individual noise reduction methods. (C) RSNA, 2014
引用
收藏
页码:849 / 862
页数:14
相关论文
共 51 条
[1]
Effect of Altering Automatic Exposure Control Settings and Quality Reference mAs on Radiation Dose, Image Quality, and Diagnostic Efficacy in MDCT Enterography of Active Inflammatory Crohn's Disease [J].
Allen, Brian C. ;
Baker, Mark E. ;
Einstein, David M. ;
Remer, Erick M. ;
Herts, Brian R. ;
Achkar, Jean-Paul ;
Davros, William J. ;
Novak, Eric ;
Obuchowski, Nancy A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) :89-100
[2]
[Anonymous], 2009, J RADIOLOGICAL PROTE
[3]
Effect of nonlinear three-dimensional optimized reconstruction algorithm filter on image quality and radiation dose: Validation on phantoms [J].
Bai, Mei ;
Chen, Jiuhong ;
Raupach, Rainer ;
Suess, Christoph ;
Tao, Ying ;
Peng, Mingchen .
MEDICAL PHYSICS, 2009, 36 (01) :95-97
[4]
Contrast-to-Noise Ratio and Low-Contrast Object Resolution on Full- and Low-Dose MDCT: SAFIRE Versus Filtered Back Projection in a Low-Contrast Object Phantom and in the Liver [J].
Baker, Mark E. ;
Dong, Frank ;
Primak, Andrew ;
Obuchowski, Nancy A. ;
Einstein, David ;
Gandhi, Namita ;
Herts, Brian R. ;
Purysko, Andrei ;
Remer, Erick ;
Vachani, Neil .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (01) :8-18
[5]
Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[6]
Determination of the presampled MTF in computed tomography [J].
Boone, JM .
MEDICAL PHYSICS, 2001, 28 (03) :356-360
[7]
Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[8]
Bruder H, 2000, IEEE T MED IMAGING, V19, P873, DOI 10.1109/42.887836
[9]
Reducing Radiation Dose in CT Enterography [J].
Del Gaizo, Andrew J. ;
Fletcher, Joel G. ;
Yu, Lifeng ;
Paden, Robert G. ;
Spencer, Garrett Clay ;
Leng, Shuai ;
Silva, Annelise M. ;
Fidler, Jeff L. ;
Silva, Alvin C. ;
Hara, Amy K. .
RADIOGRAPHICS, 2013, 33 (04) :1109-1124
[10]
Noise Reduction to Decrease Radiation Dose and Improve Conspicuity of Hepatic Lesions at Contrast-Enhanced 80-kV Hepatic CT Using Projection Space Denoising [J].
Ehman, Eric C. ;
Guimaraes, Luis S. ;
Fidler, Jeff L. ;
Takahashi, Naoki ;
Ramirez-Giraldo, Juan Carlos ;
Yu, Lifeng ;
Manduca, Armando ;
Huprich, James E. ;
McCollough, Cynthia H. ;
Holmes, David, III ;
Harmsen, W. Scott ;
Fletcher, Joel G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) :405-411