Application of micropellicular poly-styrene/divinylbenzene stationary phases for high-performance reversed-phase liquid chromotography electrospray mass spectrometry of proteins and peptides

被引:28
作者
Huber, CG
Kleindienst, G
Bonn, GK
机构
[1] Inst. Analyt. Chem. and Radiochem., Leopold-Franzens-University, 6020 Innsbruck
关键词
column liquid chromatography; electrospray ionization mass spectrometry; micropellicular poly-styrene/divinylbenzene; peptides and proteins;
D O I
10.1007/BF02466324
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Short columns packed with highly crosslinked 2.3 mu m poly-styrene/divinylbenzene (PS/DVB) particles were used for rapid and efficient separation of proteins and peptides by reversed-phase high-performance liquid chromatography at elevated temperatures. Enhancement of the diffusivities of the sample components at elevated temperatures together with the short diffusion pathlength with the micropellicular polymeric stationary phases were responsible for high efficiency, high speed of analysis, and short column regeneration times. Underivatized PS/DVB beads as well as PS/DVB microspheres which have been modified with polyvinylalcohol or octadecyl chains on the surface were synthesized, employed, and compared to HY-TACH-C18, a commercially available micropellicular octadecyl-silica stationary phase, for the separation of proteins, octapeptides and tryptic protein digests. Highest performance was obtained with the silica- and PS/DVB-based octadecyl stationary phases, which exhibited similar column efficiencies but different selectivities for proteins and peptides. The minimum detectability at 214 nm and the maximum loading capacity for ribonuclease A using analytical 30 x 4.6 mm I.D. columns were 10 ng (0.6 pmol) and 1 mu g, respectively. Finally, reversed-phase HPLC with a 60 x 2 mm I.D. narrow-bore column packed with micropellicular octadecyl PS/DVB was coupled successfully to electrospray mass spectrometry at a flow-rate of 0.15 mL min(-1) and on-line full-scan mass spectra for molecular mass determination and identification of proteins in the lower picomol range were obtained.
引用
收藏
页码:438 / 448
页数:11
相关论文
共 53 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
Aguilar MI, 1996, METHOD ENZYMOL, V270, P3
[3]   APPLICATION OF CAPILLARY ELECTROPHORESIS, HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, ONLINE ELECTROSPRAY MASS-SPECTROMETRY AND MATRIX-ASSISTED LASER-DESORPTION IONIZATION-TIME OF FLIGHT MASS-SPECTROMETRY TO THE CHARACTERIZATION OF SINGLE-CHAIN PLASMINOGEN-ACTIVATOR [J].
APFFEL, A ;
CHAKEL, J ;
UDIAVAR, S ;
HANCOCK, WS ;
SOUDERS, C ;
PUNGOR, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) :41-60
[4]  
Banks JF, 1996, METHOD ENZYMOL, V270, P486
[5]   LC/ESI-MS DETERMINATION OF PROTEINS USING CONVENTIONAL LIQUID-CHROMATOGRAPHY AND ULTRASONICALLY ASSISTED ELECTROSPRAY [J].
BANKS, JF ;
QUINN, JP ;
WHITEHOUSE, CM .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3688-3695
[6]  
BONN GK, Patent No. 398973
[7]   SOLVENT STRENGTH STUDIES ON POLYSTYRENE-DIVINYLBENZENE COLUMNS [J].
BOWERS, LD ;
PEDIGO, S .
JOURNAL OF CHROMATOGRAPHY, 1986, 371 :243-251
[8]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[10]  
Covey T, 1996, ACS SYM SER, V619, P21