Reference values of the bioelectrical impedance vector in neonates in the first week after birth

被引:31
作者
Piccoli, A
Fanos, V
Peruzzi, L
Schena, S
Pizzini, C
Borgione, S
Bertino, E
Chiaffoni, G
Coppo, R
Tatò, L
机构
[1] Univ Padua, Dipartimento Sci Med & Chirurg, Policlin Piano 4, I-35128 Padua, Italy
[2] Univ Verona, Dept Pediat, I-37100 Verona, Italy
[3] Regina Margherita Childrens Hosp, Turin, Italy
关键词
bioelectrical impedance analysis; reference values; impedance vector; infant; newborn; body composition analysis;
D O I
10.1016/S0899-9007(02)00795-5
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
OBJECTIVE: To determine the reference, bivariate, tolerance intervals of the whole-body impedance vector for healthy white neonates, we performed an observational, cross-sectional study in two university hospitals. METHODS: The impedance vector (standard, tetrapolar analysis at 50-kHz frequency) was measured in 163 consecutive subjects (87 boys and 76 girls) with postnatal ages of I to 7 d. Bivariate vector analysis was conducted with the resistance-reactance (RXc) graph method. RESULTS: The age-specific 95% confidence intervals of mean vectors and the 95%, 75%, and 50% tolerance intervals for individual vector measurements were plotted using R and Xc components standardized by the subject's crown-to-heel length (height). Mean vectors from the groups (1, 2, and 3 to 7 d) with overlapping 95% confidence ellipses were considered representative of only one age class of I to 7 d, The impedance vector distribution of neonates also was compared with healthy white children (1014 buys and 1030 girls, age 2-15 y) and adult subjects (354 men and 372 women, age 15-85 y) from the same geographic area. There was a definite, progressive, vector shortening from birth, through ages 2 to 15 y. toward the adults' vector position. CONCLUSIONS: We established the reference. bivariate, 95%, 75%, and 50% tolerance intervals of the impedance vector in the first postnatal week for healthy white neonates, with which the vectors from infant,, with altered body composition can be tested (free software is available from apiccoli@unipd.it). (C)Elsevier Science Inc. 2002.
引用
收藏
页码:383 / 387
页数:5
相关论文
共 24 条
[21]   A NEW METHOD FOR MONITORING BODY-FLUID VARIATION BY BIOIMPEDANCE ANALYSIS - THE RXC GRAPH [J].
PICCOLI, A ;
ROSSI, B ;
PILLON, L ;
BUCCIANTE, G .
KIDNEY INTERNATIONAL, 1994, 46 (02) :534-539
[22]   Discriminating between body fat and fluid changes in the obese adult using bioimpedance vector analysis [J].
Piccoli, A ;
Brunani, A ;
Savia, G ;
Pillon, L ;
Favaro, E ;
Berselli, ME ;
Cavagnini, F .
INTERNATIONAL JOURNAL OF OBESITY, 1998, 22 (02) :97-104
[23]   Estimation of total body water in very-low-birth-weight infants by using anthropometry with and without bioelectrical impedance and H2[18O] [J].
Raghavan, CV ;
Super, DM ;
Chatburn, RL ;
Savin, SM ;
Fanaroff, AA ;
Kalhan, SC .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1998, 68 (03) :668-674
[24]   Assessment of total body water using bioelectrical impedance analysis in neonates receiving intensive care [J].
Tang, W ;
Ridout, D ;
Modi, N .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1997, 77 (02) :F123-F126