Measurement of the arterial concentration of Gd-DTPA using MRI: A step toward quantitative perfusion imaging

被引:198
作者
FritzHansen, T [1 ]
Rostrup, E [1 ]
Larsson, HBW [1 ]
Sondergaard, L [1 ]
Ring, P [1 ]
Henriksen, O [1 ]
机构
[1] UNIV COPENHAGEN,HVIDOVRE HOSP,DEPT CLIN PHYSIOL & NUCL MED,DK-2650 HVIDOVRE,DENMARK
关键词
arterial input function; gadolinium-DTPA; MRI; turbo-FLASH;
D O I
10.1002/mrm.1910360209
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and <7% at downslope was found. The study also indicates that a short inversion time <250 ms has to be used to ensure correct measurement of peak concentration.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 19 条
[1]   SPIN-LATTICE RELAXATION-TIME MEASUREMENT BY MEANS OF A TURBOFLASH TECHNIQUE [J].
BLUML, S ;
SCHAD, LR ;
STEPANOW, B ;
LORENZ, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) :289-295
[2]   FACTORS IN MYOCARDIAL PERFUSION IMAGING WITH ULTRAFAST MRI AND GD-DTPA ADMINISTRATION [J].
BURSTEIN, D ;
TARATUTA, E ;
MANNING, WJ .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) :299-305
[3]   ADVANCES IN CARDIAC APPLICATIONS OF SUBSECOND FLASH MRI [J].
CHIEN, D ;
MERBOLDT, KD ;
HANICKE, W ;
BRUHN, H ;
GYNGELL, ML ;
FRAHM, J .
MAGNETIC RESONANCE IMAGING, 1990, 8 (06) :829-836
[4]   NICKEL-DOPED AGAROSE-GEL PHANTOMS IN MR IMAGING [J].
CHRISTOFFERSSON, JO ;
OLSSON, LE ;
SJOBERG, S .
ACTA RADIOLOGICA, 1991, 32 (05) :426-431
[5]   QUANTIFICATION OF MYOCARDIAL BLOOD-FLOW AND EXTRACELLULAR VOLUMES USING A BOLUS INJECTION OF GD-DTPA - KINETIC MODELING IN CANINE ISCHEMIC DISEASE [J].
DIESBOURG, LD ;
PRATO, FS ;
WISENBERG, G ;
DROST, DJ ;
MARSHALL, TP ;
CARROLL, SE ;
ONEILL, B .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :239-253
[6]  
FRITZHANSEN T, 1995, P SMR 3 ANN M, P878
[7]   MEASUREMENT OF ABSOLUTE BLOOD IODINE CONCENTRATION DURING DIGITAL SUBTRACTION VENTRICULOGRAPHY [J].
FUERST, TP ;
VANLYSEL, MS .
MEDICAL PHYSICS, 1993, 20 (03) :795-803
[8]   NUCLEAR MAGNETIC-RESONANCE SIGNAL FROM FLOWING NUCLEI IN RAPID IMAGING USING GRADIENT ECHOES [J].
GAO, JH ;
HOLLAND, SK ;
GORE, JC .
MEDICAL PHYSICS, 1988, 15 (06) :809-814
[9]   ERROR ANALYSIS OF A QUANTITATIVE CEREBRAL BLOOD-FLOW MEASUREMENT USING (H2O)-O-15 AUTORADIOGRAPHY AND POSITRON EMISSION TOMOGRAPHY, WITH RESPECT TO THE DISPERSION OF THE INPUT FUNCTION [J].
IIDA, H ;
KANNO, I ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1986, 6 (05) :536-545
[10]   A SYSTEM FOR CEREBRAL BLOOD-FLOW MEASUREMENT USING AN (H2O)-O-15 AUTORADIOGRAPHIC METHOD AND POSITRON EMISSION TOMOGRAPHY [J].
KANNO, I ;
IIDA, H ;
MIURA, S ;
MURAKAMI, M ;
TAKAHASHI, K ;
SASAKI, H ;
INUGAMI, A ;
SHISHIDO, F ;
UEMURA, K .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1987, 7 (02) :143-153